Siemens 3RV1031-4AA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1031-4AA15 SIRIUS Motor Protection Circuit Breake

MPN3RV1031-4AA15

Siemens SIRIUS motor protection circuit breaker, 3RV1031-4AA15, 16 A continuous rated current, Class 10 trip, 7.5 kW at 400 V AC-3, screw terminals, snap-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1031-4AA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1031-4AA15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W
3RV1031-4AA15 — Protection & Tripping
ParameterValue
Overload release setting range11 ... 16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1031-4AA15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1031-4AA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1031-4AA15 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1031-4AA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1031-4AA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1031-4AA15 is a SIRIUS motor protection circuit breaker rated 16 A continuous current, with a Class 10 trip characteristic and a rated power of 7.5 kW at 400 V in AC-3 duty. That 7.5 kW figure at 400 V tells you the motor size it's sized for — a standard 7.5 kW four-pole induction motor on a 400 V three-phase line. The Class 10 trip means it will clear a stalled-rotor condition within 10 seconds at seven times the thermal setting, which is the standard protection for standard squirrel-cage motors. It includes phase failure detection as standard, so if one phase drops, the breaker trips before the motor single-phases and burns out. At 240 V AC it handles 100 kA, at 500 V AC it's 12 kA, and at 690 V AC it drops to 5 kA — so if your panel's available fault current exceeds those numbers at the respective voltage, you need to coordinate with a backup fuse or a higher-rated breaker upstream.

Mounting and wiring — DIN rail, screw terminals, IP20 front

Zero mm clearance required at the back and at the sides — you can butt it against the enclosure wall or adjacent devices without derating for airflow blockage. Main circuit terminals are screw-type with box terminals, accepting stranded wire from 0.75 mm² up to 35 mm² for a single conductor, or 2x 25 mm² for two conductors. Solid wire acceptance is 2x 0.5 to 1.5 mm² or 2x 0.75 to 2.5 mm². The auxiliary and control circuit terminals are also screw-type. Dimensions are 55 mm wide, 140 mm high, 149 mm deep — the depth is the dimension that sticks out from the DIN rail, so if your enclosure depth is tight, that 149 mm is the number to check against the door clearance.

Lifecycle and sourcing — current production, quoted to order

Duty cycle and thermal dissipation — 15 ops/h AC-3, 14.5 W heat loss

Maximum operating frequency in AC-3 duty is 15 operations per hour. That's the switching limit for motor starting under load — if your application cycles faster than every four minutes, this breaker will overheat the bimetal strip and nuisance-trip. The power dissipation in hot operating state is 14.5 W at rated current, which is the heat it dumps into the enclosure. For a panel with multiple breakers ganged together, sum those 14.5 W per unit and check the enclosure's thermal rise.

Frequently asked questions

What is the breaking capacity of 3RV1031-4AA15 at 400 V?

At 400 V AC the breaking capacity is 50 kA. At 240 V AC it is 100 kA, at 500 V AC it is 12 kA, and at 690 V AC it is 5 kA.

What wire sizes does the 3RV1031-4AA15 accept on the main terminals?

The screw-type box terminals accept stranded wire: 2x 0.75 to 25 mm² or 1x 0.75 to 35 mm². Solid wire: 2x 0.5 to 1.5 mm² or 2x 0.75 to 2.5 mm². AWG equivalents are 2x 18 to 2 or 1x 18 to 2.

Does 3RV1031-4AA15 include phase failure protection?

Yes, phase failure detection is standard. Ground fault detection is not included on this model.

Where can I buy 3RV1031-4AA15 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

What compliance documentation is available for 3RV1031-4AA15?

RoHS compliance is documented with a substance prohibition date of July 1, 2006. The part carries IP20 front protection. Full documentation including datasheet, CE declaration, and UL file information is available from the manufacturer.