Siemens 3RV1031-4DA10-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1031-4DA10-0BA0 SIRIUS Motor Protection Circuit B

MPN3RV1031-4DA10-0BA0

Siemens SIRIUS 3RV1031-4DA10-0BA0 motor protection circuit breaker, 25 A rated continuous current, Class 10 trip, 50 kA breaking capacity at 400 V AC, screw-type terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1031-4DA10-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1031-4DA10-0BA0 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W
3RV1031-4DA10-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range18 ... 25 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1031-4DA10-0BA0 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1031-4DA10-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1031-4DA10-0BA0 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1031-4DA10-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1031-4DA10-0BA0 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Breaking capacity is 50 kA at 400 V AC, 100 kA at 240 V AC, 12 kA at 500 V AC, and 5 kA at 690 V AC — covering most industrial supply points without needing an upstream current-limiting fuse for high-fault panels. Built-in phase failure detection trips the breaker if one phase drops out, preventing single-phasing damage on three-phase motors. No ground fault detection — that's handled separately if needed.

Dimensions are 55 mm wide, 140 mm high, 149 mm deep — fits a standard 3-pole MCCB slot. No side clearance needed (0 mm backwards, 0 mm at the side) so you can pack breakers tight on the rail. Main terminals accept 2x solid conductors up to 16 mm² or 2x stranded up to 25 mm² (1x up to 35 mm²). AWG equivalents: 2x 18–2 AWG solid, 1x 18–2 AWG. Finely stranded with ferrules: 2x 0.75–16 mm² or 0.75–25 mm² single.

Shock rated 25g for 11 ms. IP20 protection on the front (finger-safe, not washdown). RoHS compliance date: July 1, 2006. Mounting position any — no derating for side or upside-down installation. Power dissipation: 14.5 W total in hot operating state, 4.8 W per pole. At 15 operations per hour maximum (AC-3 duty), thermal management in a sealed enclosure is straightforward.

Frequently asked questions

What wire sizes does the 3RV1031-4DA10-0BA0 accept?

Main screw terminals accept 2x solid up to 16 mm², 2x stranded up to 25 mm², or 1x stranded up to 35 mm². AWG equivalent: 2x 18–2.

Does the 3RV1031-4DA10-0BA0 have phase failure protection?

Yes, built-in phase failure detection trips the breaker if one phase is lost. No ground fault detection — that's separate.

MPN
3RV1031-4DA10-0BA0