Skip to main content
Siemens 3RV1031-4EA10-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1031-4EA10-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1031-4EA10-ZW98

Siemens SIRIUS motor protection circuit breaker, 3RV1031-4EA10-ZW98, 32 A continuous, 15 kW at 400 V, CLASS 10 trip, screw terminals, IP20 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1031-4EA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1031-4EA10-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)19 W
Power loss, per pole (AC, hot)6.3 W
3RV1031-4EA10-ZW98 — Protection & Tripping
ParameterValue
Overload release setting range22 ... 32 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1031-4EA10-ZW98 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1031-4EA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1031-4EA10-ZW98 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1031-4EA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1031-4EA10-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1031-4EA10-ZW98 is a SIRIUS motor protection circuit breaker rated for 32 A continuous current and 15 kW at 400 V AC-3 duty.

Breaking capacity is 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. That simplifies panel coordination: you can feed it from a standard 50 kA-rated bus without adding a fuse block.

The main circuit accepts 2x (0.75…16 mm²) solid or 2x (0.75…25 mm²) stranded, plus a single 0.75…35 mm² stranded — enough for the 32 A feed without doubling up. Auxiliary switch extension is supported, so you can add a remote trip-indication contact without a separate interposing relay.

Frequently asked questions

Can I add an auxiliary switch to this breaker?

Yes, the product extension auxiliary switch is supported, so you can add remote trip indication.

What compliance documentation does this part carry?

RoHS compliance dated 07/01/2006; IP20 front protection.