Siemens 3RV1031-4EB10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1031-4EB10 SIRIUS Motor Protection Circuit Breake

MPN3RV1031-4EB10

Siemens SIRIUS motor protection circuit breaker, 3RV1031-4EB10, 32 A rated continuous current, Class 20 trip, 50 kA breaking capacity at 400 V AC, screw-type terminals, for DIN rail mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1031-4EB10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1031-4EB10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)19 W
Power loss, per pole (AC, hot)6.3 W
3RV1031-4EB10 — Protection & Tripping
ParameterValue
Overload release setting range22 ... 32 A
Trip classCLASS 20
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1031-4EB10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1031-4EB10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1031-4EB10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1031-4EB10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1031-4EB10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor Protection Circuit Breaker for 32 A Loads

Its Class 20 trip characteristic means it allows up to 20 seconds to trip at 7.2× rated current — the standard for standard-duty induction motors driving pumps, fans, and compressors where starting transients last several seconds. No ground-fault detection on this unit; that is handled separately downstream if required. Breaking capacity is 50 kA at 400 V AC, 100 kA at 240 V, dropping to 10 kA at 500 V and 4 kA at 690 V. At 400 V — the most common industrial supply — this breaker can interrupt a 50 kA prospective fault current without upstream fusing, which covers most panelboard and motor control center applications.

Any mounting position is permitted. Dimensions: 55 mm wide, 140 mm high, 149 mm deep — fits a standard 55 mm module slot. Zero clearance required at the sides or rear, so breakers can be ganged without spacing. Main circuit terminals accept solid conductors 2x (0.75…16 mm²) or stranded 2x (0.75…25 mm²) and up to 1x 35 mm². AWG equivalents: 2x (18…2). Control circuit terminals are screw-type as well.

Shock resistance rated at 25 g for 11 ms. IP20 protection on the front — suitable for enclosed panels where the front is operator-accessible but not washdown-rated.

Frequently asked questions

What is the breaking capacity of 3RV1031-4EB10 at 400 V?

50 kA at 400 V AC. It also carries 100 kA at 240 V, 10 kA at 500 V, and 4 kA at 690 V.

What wire sizes does the 3RV1031-4EB10 accept?

Main circuit terminals accept solid 2x (0.75…16 mm²), stranded 2x (0.75…25 mm²), and up to 1x 35 mm². AWG equivalents are 2x (18…2).

Where can I buy 3RV1031-4EB10?

Sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing.

Does 3RV1031-4EB10 include phase failure protection?

Yes, phase failure detection is built in. Ground fault detection is not included on this unit.