Skip to main content
Siemens 3RV1031-4GA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1031-4GA10-0FJ0-ZX95 SIRIUS Motor Protection Circ

MPN3RV1031-4GA10-0FJ0-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1031-4GA10-0FJ0-ZX95, 45 A rated continuous current, 22 kW at 400 V AC-3, CLASS 10 trip, screw terminals, DIN-rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1031-4GA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1031-4GA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)29 W
Power loss, per pole (AC, hot)9.7 W

Protection & Tripping

3RV1031-4GA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1031-4GA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1031-4GA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²

Mechanical

3RV1031-4GA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting positionany

Environmental

3RV1031-4GA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1031-4GA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS 3RV1031-4GA10-0FJ0-ZX95 — motor protection circuit breaker, 45 A

The Siemens SIRIUS 3RV1031-4GA10-0FJ0-ZX95 is a motor-protection circuit breaker rated for 45 A continuous current, sized for a 22 kW motor at 400 V AC-3 duty. CLASS 10 trip characteristic means it clears a locked-rotor condition within 10 seconds at 7.2× rated current — standard protection for standard induction motors driving pumps, fans, and conveyors. Phase failure detection is built in, so a single-phased motor trips before winding damage sets in. Breaking capacity runs 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. At 400 V — the most common industrial distribution voltage — 50 kA SCCR covers nearly any panel fed from a typical transformer, so you rarely need an upstream current-limiting fuse for coordination. Mounts via screw or snap-on onto 35 mm DIN rail per EN 50022. Screw-type box terminals on the main circuit accept solid conductors 2x 0.75–16 mm² and stranded up to 2x 0.75–25 mm² or single 0.75–35 mm². No auxiliary contacts included (0 built-in), but the unit accepts an add-on auxiliary switch block — the provision is there.

Environmental and installation limits

Rated for operation from -20 to +60 °C, storage and transport from -50 to +80 °C. IP20 finger-safe front. Shock rated at 25 g / 11 ms. Mounting position any — no derating needed for horizontal or vertical orientation. Zero clearance at sides and rear saves panel width.

Frequently asked questions

Where can I buy 3RV1031-4GA10-0FJ0-ZX95 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What are the key ratings of 3RV1031-4GA10-0FJ0-ZX95?

Rated continuous current 45 A, motor rating 22 kW at 400 V AC-3, CLASS 10 trip, breaking capacity 50 kA at 400 V AC.

What wire sizes does the 3RV1031-4GA10-0FJ0-ZX95 accept?

Screw-type terminals accept solid 2x 0.75–16 mm² and stranded 2x 0.75–25 mm² or single 0.75–35 mm².

MPN
3RV1031-4GA10-0FJ0-ZX95