Specifications

3RV1031-4HB15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1031-4HB15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)29 W
Power loss, per pole (AC, hot)9.7 W
3RV1031-4HB15 — Protection & Tripping
ParameterValue
Overload release setting range40 ... 50 A
Trip classCLASS 20
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1031-4HB15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1031-4HB15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1031-4HB15 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1031-4HB15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1031-4HB15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Trip Class 20 means it allows a motor starting current of up to 7.2x the thermal setting for 20 seconds before tripping — a good match for standard induction motors driving pumps, fans, or conveyors that don't have extended start times. It includes phase failure detection but no ground fault detection, so it handles the most common motor fault — a lost phase — without nuisance tripping on leakage.

The 3RV1031-4HB15 delivers 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. At 400 V — the most common industrial supply in Europe and Asia — 50 kA SCCR gives you headroom for high-fault panels without needing a current-limiting upstream breaker. Compared to the 3RV2021-4NA25, which is a newer SIRIUS 3RV2 frame with a different trip curve and higher breaking capacity at 690 V, this 3RV1 series part is the established choice for 400 V distribution where the 50 kA rating is sufficient. The 3RV2 has a slightly different footprint — verify DIN rail spacing if swapping.

Width is 55 mm, height 140 mm, depth 149 mm — plan your gland plate and wireway clearance accordingly. Main circuit terminals accept solid 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²), or stranded 2x (0.75...25 mm²) and 1x (0.75...35 mm²). Auxiliary and control circuit terminals are screw-type. AWG equivalents for main contacts: 2x (18...2), 1x (18...2).

Substance prohibitance date of 07/01/2006 aligns with RoHS compliance. Storage temperature range -50 to +80 °C, operation -20 to +60 °C, transport -50 to +80 °C. Shock resistance rated at 25g / 11 ms.