Skip to main content
Siemens 3RV1041-4HA10-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1041-4HA10-ZW95 SIRIUS Motor Protection Circuit B

MPN3RV1041-4HA10-ZW95

Siemens SIRIUS motor protection circuit breaker, 3RV1041-4HA10-ZW95, 50 A continuous current, 22 kW at 400 V AC-3, CLASS 10 trip, screw terminals, IP20 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1041-4HA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1041-4HA10-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)27 W
Power loss, per pole (AC, hot)9 W
3RV1041-4HA10-ZW95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1041-4HA10-ZW95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV1041-4HA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 2.5 ... 50 mm²
3RV1041-4HA10-ZW95 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth174 mm
Mounting positionany
3RV1041-4HA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1041-4HA10-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1041-4HA10-ZW95 is a motor protection circuit breaker designed for motor loads up to 22 kW at 400 V AC-3 duty, with a continuous current rating of 50 A.

Breaking capacity — where it interrupts

This breaker clears faults at 100 kA at 240 V AC, 50 kA at 400 V AC, 12 kA at 500 V AC, and 6 kA at 690 V AC (–). That's the interrupting capacity at each voltage level — the higher the line voltage, the harder the arc is to extinguish, so the rating drops. For a 400 V panel, 50 kA SCCR covers most industrial service entrances; at 690 V the 6 kA figure still handles downstream faults in a motor control center.

Shock rated at 25g for 11 ms — survives shipping drops and machine vibration.

Main circuit terminals are screw-type with box terminals, accepting solid conductors 2x (2.5 to 16 mm²) and stranded 2x (10 to 50 mm²) or 1x (10 to 70 mm²). That's enough cross-section for 50 A feeds with some headroom. Finely stranded with core end processing goes up to 2x (2.5 to 35 mm²) or 2.5 to 50 mm². AWG equivalents: 2x (10 to 1 AWG) solid, 1x (10 to 2 AWG) stranded.

Frequently asked questions

Where can I buy 3RV1041-4HA10-ZW95 and how do I get a price?

This part is sourced and quoted to order through our independent distribution network. Submit an RFQ for current pricing and availability — figures are confirmed at quote time, not on a public listing.

What is 3RV1041-4HA10-ZW95's listed depth?

The depth is 174 mm. That's the dimension from the DIN rail mounting surface to the front of the housing — relevant for enclosure depth planning.

What compliance documentation does this brand provide for 3RV1041-4HA10-ZW95?

As a Siemens SIRIUS catalog item, it carries CE marking for the European market and is designed to meet IEC/EN 60947-2 and 60947-4-1 standards for circuit breakers and motor starters. RoHS and REACH compliance documentation is available from the manufacturer upon request.

Will 3RV1041-4HA10-ZW95 drop into a panel specified around 3RV6011-0CA10 without rewiring?

Not directly. The 3RV1041-4HA10-ZW95 is a SIRUS 3RV1 frame size with different mounting footprint and terminal layout than the 3RV6 series. Panel cutouts and DIN rail position may differ — verify mechanical dimensions before substitution.

MPN
3RV1041-4HA10-ZW95