Siemens 3RV1041-4HA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1041-4HA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1041-4HA10-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1041-4HA10-ZX95, 50 A continuous rated, CLASS 10 trip class, 22 kW at 400 V, 3-pole, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1041-4HA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1041-4HA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)27 W
Power loss, per pole (AC, hot)9 W
3RV1041-4HA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range36 ... 50 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1041-4HA10-ZX95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1041-4HA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 2.5 ... 50 mm²
Conductor range, AWG (main contacts)2x (10 ... 1), 1x (10 ... 2)
3RV1041-4HA10-ZX95 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth174 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1041-4HA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1041-4HA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Zero clearance needed at the sides or rear — the 70 mm width and 165 mm height fit tight sub-panels; the 174 mm depth leaves room for gland plates. Screw-type box terminals on the main circuit accept 2x solid (2.5 to 16 mm²) or 2x stranded (10 to 50 mm²) with a single 70 mm² option. AWG 10 to 1/0 on the mains. Wire up without derating for side-by-side packing.

Protection and ratings

Phase-failure detection is built in; ground-fault detection is not. The 690 V rated insulation voltage and 6 kV surge withstand suit it for 480/277 V and 600 V nominal systems.

Frequently asked questions

Where can I buy the 3RV1041-4HA10-ZX95?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of this breaker at 400 V?

50 kA at 400 V AC. Also rated 100 kA at 240 V, 12 kA at 500 V, and 6 kA at 690 V.

Does the 3RV1041-4HA10-ZX95 fit on a standard DIN rail?

Yes, it snaps onto 35 mm mounting rail per DIN EN 50022. Requires zero clearance at the sides or rear for mounting.

What wire sizes does the main circuit accept?

Solid: 2x (2.5 to 16 mm²). Stranded: 2x (10 to 50 mm²) or 1x (10 to 70 mm²). AWG equivalents 10 to 1/0.

MPN
3RV1041-4HA10-ZX95