3RV1041-4JA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1041-4JA10-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)34 W
Power loss, per pole (AC, hot)11.3 W
3RV1041-4JA10-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range45 ... 63 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1041-4JA10-ZW95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1041-4JA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 2.5 ... 50 mm²
Conductor range, AWG (main contacts)2x (10 ... 1), 1x (10 ... 2)
3RV1041-4JA10-ZW95 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth174 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1041-4JA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1041-4JA10-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1041-4JA10-ZW95 is a SIRIUS motor protection circuit breaker rated for 63 A continuous current and 30 kW at 400 V AC-3 duty, with a Class 10 trip characteristic. It is designed for motor protection in main current circuits, with screw-type box terminals for the main circuit and separate screw terminals for the auxiliary and control circuit. The 63 A continuous rating means this breaker handles motor full-load currents up to that level; the 30 kW at 400 V figure is the typical three-phase motor it protects. Breaking capacity is 100 kA at 240 V AC, 50 kA at 400 V AC, 12 kA at 500 V AC, and 6 kA at 690 V AC — sufficient for most industrial panel fault levels without cascading upstream.

Any mounting position is allowed. Terminal capacity: solid conductors 2x (2.5 to 16 mm²); stranded 2x (10 to 50 mm²) or 1x (10 to 70 mm²). AWG equivalents for main contacts: 2x (10 to 1 AWG), 1x (10 to 2 AWG). Finely stranded with core-end processing: 2x (2.5 to 35 mm²) or 2.5 to 50 mm². No backwards or side clearance required. Power dissipation at rated current is 34 W total, 11.3 W per pole in hot operating state.

Shock resistance is 25 g for 11 ms. Surge voltage resistance rated at 6000 V. Maximum operating frequency in AC-3 duty is 15 operations per hour.