Siemens 3RV1041-4JA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1041-4JA15 SIRIUS Motor Protection Circuit Breake

MPN3RV1041-4JA15

Siemens SIRIUS 3RV1041-4JA15 motor protection circuit breaker, 63 A continuous, CLASS 10 trip, 30 kW at 400 V AC-3, screw terminals, 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1041-4JA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1041-4JA15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)34 W
Power loss, per pole (AC, hot)11.3 W
3RV1041-4JA15 — Protection & Tripping
ParameterValue
Overload release setting range45 ... 63 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1041-4JA15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1041-4JA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1041-4JA15 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth174 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Mounting positionany
3RV1041-4JA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1041-4JA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1041-4JA15 is a SIRIUS motor protection circuit breaker rated for 63 A continuous current with CLASS 10 trip characteristics, sized for a 30 kW motor at 400 V AC-3 duty. It combines short-circuit and overload protection in one device, eliminating the need for a separate overload relay on the line side of the contactor.

The 63 A continuous rating sets the upper bound for motor FLA you can protect — match it to the motor nameplate, not the supply transformer. Breaking capacity drops with voltage: 100 kA at 240 V AC, 50 kA at 400 V AC, 12 kA at 500 V AC, and 6 kA at 690 V AC. At 400 V, 50 kA covers most industrial service-entrance fault levels without needing current-limiting fuses upstream. The 6 kV surge voltage resistance (rated impulse withstand) means the insulation coordinates with standard distribution panels.

The 70 mm width, 165 mm height, and 174 mm depth are the envelope you need on the DIN rail — zero clearance required at the sides or rear, so you can butt it against adjacent devices.

Frequently asked questions

What is the breaking capacity of the 3RV1041-4JA15 at 400 V?

50 kA at 400 V AC rated value, which covers most industrial panel fault levels without upstream fuses.

What wire sizes does the 3RV1041-4JA15 accept on the main circuit?

Stranded conductors: 2x (10 to 50 mm²) or 1x (10 to 70 mm²). Solid conductors on the auxiliary circuit: 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²).

Where can I buy the 3RV1041-4JA15 and get current pricing?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.

Does the 3RV1041-4JA15 include phase-failure protection?

Yes, phase-failure detection is built in. Ground-fault detection is not included.

MPN
3RV1041-4JA15