Skip to main content
Siemens 3RV1041-4KA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1041-4KA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1041-4KA10-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1041-4KA10-ZW97, 75 A continuous, 37 kW at 400 V, 50 kA breaking capacity, CLASS 10, screw terminals, snap-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1041-4KA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1041-4KA10-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)38 W
Power loss, per pole (AC, hot)12.7 W
3RV1041-4KA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range57 ... 75 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)8 kA
Breaking capacity at 690 V (AC)5 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1041-4KA10-ZW97 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1041-4KA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 2.5 ... 50 mm²
Conductor range, AWG (main contacts)2x (10 ... 1), 1x (10 ... 2)
3RV1041-4KA10-ZW97 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth174 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1041-4KA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1041-4KA10-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Rated breaking capacity reaches 50 kA at 400 V AC, with 100 kA at 240 V, 8 kA at 500 V, and 5 kA at 690 V — so it handles high fault currents in industrial distribution without upstream cascading.

Dimensions: 70 mm wide, 165 mm high, 174 mm deep. Main circuit terminals accept solid conductors 2x (2.5–16 mm²) or stranded 2x (10–50 mm²) and 1x (10–70 mm²); auxiliary and control circuits use separate screw terminals. AWG equivalents: 2x (10–1) for solid, 2x (10–2) for stranded.

Frequently asked questions

What wire sizes does the main circuit accept?

Solid 2x (2.5–16 mm²) or stranded 2x (10–50 mm²) and 1x (10–70 mm²).

MPN
3RV1041-4KA10-ZW97