3RV1041-4LA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1041-4LA10-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)38 W
Power loss, per pole (AC, hot)12.7 W
3RV1041-4LA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range70 ... 90 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)8 kA
Breaking capacity at 690 V (AC)5 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1041-4LA10-ZW97 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1041-4LA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 2.5 ... 50 mm²
Conductor range, AWG (main contacts)2x (10 ... 1), 1x (10 ... 2)
3RV1041-4LA10-ZW97 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth174 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1041-4LA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1041-4LA10-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1041-4LA10-ZW97 is a motor-protection circuit breaker rated for 90 A continuous current, switching 45 kW at 400 V with a Class 10 trip characteristic. For a panel-builder, that means no special tooling beyond a standard screwdriver, and the 70 mm² stranded capacity handles the feed from a 90 A motor starter without a separate terminal block.

Breaking capacity and fault clearing

At 240 V it handles 100 kA, at 500 V it drops to 8 kA, and at 690 V to 5 kA. The 690 V rated value of the device is 690 V, so it can live on a 690 V line but the fault current at that level needs to stay under 5 kA.

The 70 mm width and 165 mm height fit a standard 8-module row in a 600 mm enclosure. Depth is 174 mm, so it clears a 200 mm deep gland plate with room for wiring.

Frequently asked questions

What is the breaking capacity of this breaker at 400 V?

50 kA at 400 V AC, which is the typical supply voltage for a 45 kW motor circuit in industrial panels.

What wire sizes fit the main terminals?

Solid wire accepts 2x (2.5 to 16 mm²); stranded accepts 2x (10 to 50 mm²) or 1x (10 to 70 mm²). AWG equivalents are 2x (10 to 1) for the main contacts.

Where can I buy the 3RV1041-4LA10-ZW97?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.