Siemens 3RV1041-4MA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1041-4MA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1041-4MA10-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1041-4MA10-ZX95, 100 A continuous, 45 kW at 400 V, Class 10 trip, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1041-4MA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1041-4MA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)44 W
Power loss, per pole (AC, hot)14.7 W
3RV1041-4MA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range80 ... 100 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)8 kA
Breaking capacity at 690 V (AC)5 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1041-4MA10-ZX95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1041-4MA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 2.5 ... 50 mm²
3RV1041-4MA10-ZX95 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth174 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Mounting positionany
3RV1041-4MA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1041-4MA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1041-4MA10-ZX95 is a motor protection circuit breaker rated for 100 A continuous current with a 45 kW motor rating at 400 V AC, Class 10 trip curve. The Class 10 trip means it clears overloads within 10 seconds at 7.2× the thermal setting — fast enough to protect standard induction motors during a stall or jam without nuisance tripping on normal starting inrush.

The 70 mm width and 174 mm depth fit standard panel layouts; zero clearance needed at the back or sides for heat dissipation (0 mm backwards, 0 mm at the side). Main circuit terminals accept solid conductors 2× (2.5…16 mm²) or stranded 2× (10…50 mm²), single up to 70 mm². Auxiliary and control circuit terminals are screw-type, separate from the main power path.