Siemens 3RV1321-0GC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1321-0GC10 SIRIUS Circuit Breaker, 0.63 A, 100 kA

MPN3RV1321-0GC10

Siemens SIRIUS 3RV1321-0GC10 circuit breaker for starter combinations, 0.63 A continuous, 100 kA breaking capacity at 400 V AC, 3-pole, screw terminals, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1321-0GC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1321-0GC10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1321-0GC10 — Protection & Tripping
ParameterValue
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1321-0GC10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1321-0GC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1321-0GC10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1321-0GC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1321-0GC10 — Specifications
ParameterValue
Design Of The Productfor starter combinations

Product details

Rated at 0.63 A continuous current, it protects small motor loads up to 0.18 kW at 400 V AC, with a massive 100 kA breaking capacity at 400 V — that SCCR headroom means it clears high fault currents without upstream coordination headaches.

Terminals accept solid or stranded wire: 2x 1–2.5 mm² and 2x 2.5–6 mm² per clamp, or AWG 14–10 for the main contacts. That dual-range grip handles both control wiring and power tails without piggyback lugs. Dimensions: 45 mm wide, 97 mm tall, 96 mm deep — standard 3-module footprint on the rail.

The 100 kA breaking capacity at 400 V is the same across 240 V, 500 V, and 690 V — full-range performance, no derating at higher voltages. That's unusual for a compact breaker and simplifies selectivity studies. Rated insulation voltage 690 V, surge withstand 6 kV. The 5.5 W power dissipation at rated current (1.8 W per pole) is low enough that you can pack these side-by-side without thermal derating in most enclosures. No ground fault or phase failure detection built in — this is a straightforward thermal-magnetic breaker for starter duty. If you need those functions, add an external relay or step up to the SIRIUS 3RV2 series with electronic trip. Operating frequency max 15 operations per hour at AC-3 — fine for occasional start/stop on a conveyor or pump, not for high-cycling applications like a stamping press.