Skip to main content
Siemens 3RV1331-4EC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1331-4EC10 SIRIUS Circuit Breaker, 32 A, 50 kA at

MPN3RV1331-4EC10

Siemens SIRIUS 3RV1331-4EC10 circuit breaker for starter combinations, 32 A continuous rated current, 50 kA breaking capacity at 400 V AC, screw-type terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1331-4EC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1331-4EC10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)19 W
Power loss, per pole (AC, hot)6.3 W
3RV1331-4EC10 — Protection & Tripping
ParameterValue
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1331-4EC10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1331-4EC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1331-4EC10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1331-4EC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1331-4EC10 — Specifications
ParameterValue
Design Of The Productfor starter combinations

Product details

Rated for 32 A continuous current and 690 V maximum, it handles motor loads up to 15 kW at 400 V AC-3 duty.

Breaking capacity drops with voltage: 100 kA at 240 V AC, 50 kA at 400 V, 10 kA at 500 V, and 4 kA at 690 V.

The box terminals accept solid conductors 2x (0.75...16 mm²) and stranded 2x (0.75...25 mm²) or 1x (0.75...35 mm²). Zero clearance required at the sides and rear — you can butt multiple units together without derating. Mounting position is any, which helps in tight enclosures.

Current production — no phase-out notice on this order code. The SIRIUS family is Siemens' mainstream motor protection platform, so supply is steady through standard distribution. Same part, different passport — if you're sourcing cross-border, the genuine article is the same regardless of which Siemens region it came from, though warranty terms may vary by origin.

Shock rated at 25g for 11 ms. RoHS compliance date marked as July 1, 2006 — the part meets the original EU RoHS directive. No ground fault or phase failure detection built in; this is a straightforward thermal-magnetic breaker for motor circuits, not a multifunction protection relay.

MPN