Siemens 3RV1342-4JC10 SIRIUS Circuit Breaker, 63 A, 100 kA a

MPN3RV1342-4JC10

Siemens SIRIUS circuit breaker for starter combinations, 3RV1342-4JC10, 63 A continuous, 100 kA breaking at 400 V, 30 kW motor rating at 400 V, 3-pole, screw terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1342-4JC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1342-4JC10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)34 W
Power loss, per pole (AC, hot)11.3 W
3RV1342-4JC10 — Protection & Tripping
ParameterValue
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)15 kA
Breaking capacity at 690 V (AC)7.5 kA
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1342-4JC10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1342-4JC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 2.5 ... 50 mm²
Conductor range, AWG (main contacts)2x (10 ... 1), 1x (10 ... 2)
3RV1342-4JC10 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth174 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1342-4JC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1342-4JC10 — Specifications
ParameterValue
Design Of The Productfor starter combinations

Product details

What this SIRIUS breaker does in the panel

The Siemens 3RV1342-4JC10 is a 3-pole circuit breaker from the SIRIUS family, designed specifically for starter combinations — meaning it integrates directly with contactors to form a coordinated motor starter pair. Rated 63 A continuous and 30 kW at 400 V (AC-3), it handles the motor branch circuit for pumps, conveyors, and compressors up to that load. The IP20 front protection means it's finger-safe for the panel builder but expects an enclosure door for washdown or outdoor duty.

Breaking capacity and selectivity at a glance

Breaking capacity drops with voltage: 100 kA at 240 V and 400 V, then 15 kA at 500 V, and 7.5 kA at 690 V. The 690 V rating of 7.5 kA still covers most motor branch faults on 690 V industrial networks.

Main circuit terminals accept solid conductors 2x (2.5... 16 mm²) and stranded 2x (10... 50 mm²) or 1x (10... 70 mm²). For AWG, 2x (10... 1) solid and 1x (10... 2) stranded. The screw-type box terminals are standard for panel builders — no special tooling needed. Auxiliary and control circuits use separate screw terminals.

Shock resistance 25g / 11 ms. RoHS compliance date 07/01/2006 (substance prohibitance).

Frequently asked questions

Where can I buy 3RV1342-4JC10 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 3RV1342-4JC10's breaking capacity at 400 V?

100 kA at 400 V AC — the same as at 240 V, dropping to 15 kA at 500 V and 7.5 kA at 690 V.

What compliance documentation does this brand provide for 3RV1342-4JC10?

RoHS compliance is documented with a substance prohibitance date of 07/01/2006. The part carries IP20 front protection and finger-safe touch protection.

Will 3RV1342-4JC10 drop into a panel specified around 3RV6021-4DA10 without rewiring?

Both are 3-pole SIRIUS breakers on 35 mm DIN rail with zero side/rear clearance, so the footprint is identical. Terminal capacity differs — verify conductor sizes against your existing wiring before swapping.