Skip to main content
Siemens 3RV1353-6BP10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1353-6BP10 SIRIUS MCCB, 1.6 A, 85 kA @ 400 V

MPN3RV1353-6BP10

Siemens SIRIUS molded-case circuit breaker, 3RV1353-6BP10, 3-pole, 1.6 A rated continuous current, 85 kA breaking capacity at 400 V AC, screw terminals, IP20 front, current production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1353-6BP10 — Identification
ParameterValue
SeriesSIRIUS
Product designationmolded-case circuit breaker
3RV1353-6BP10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)8 000 V
Number of poles3
3RV1353-6BP10 — Protection & Tripping
ParameterValue
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)85 kA
Breaking capacity at 500 V (AC)50 kA
Breaking capacity at 690 V (AC)10 kA
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1353-6BP10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1353-6BP10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
3RV1353-6BP10 — Mechanical
ParameterValue
Height130 mm
Width90 mm
Depth70 mm
Mounting methodscrew fixing
Mounting positionany
3RV1353-6BP10 — Environmental
ParameterValue
Operating temperature-25 ... +70 °C
Storage temperature-40 ... +70 °C
Transport temperature-40 ... +70 °C
Max. installation altitude2 000 m
3RV1353-6BP10 — Specifications
ParameterValue
Design Of The Productfor starter combinations

Product details

Three-pole, rated 1.6 A continuous current, with a magnetic overcurrent and short-circuit release (no thermal element). Finger-safe IP20 front protection means an operator can touch the front of the installed breaker without shock risk — standard for enclosed panels.

The interrupting rating drops as system voltage rises: 100 kA at 240 V AC, 85 kA at 400 V, 50 kA at 500 V, and 10 kA at 690 V. For a 400 V panel with a transformer rating under 2 MVA, 85 kA is ample — most industrial MCCs spec 65 kA or less. The AC-3 motor-switching rating is 1.6 A at 400 V, same as the continuous rating, so this breaker is sized for a motor full-load current up to 1.6 A — roughly a 0.37 kW motor at 400 V.

Main circuit terminals are screw-type on the front side; auxiliary and control circuit terminals are also screw-type.

Frequently asked questions

What compliance documentation does this breaker carry?

RoHS compliance effective 2008-01-08. The SIRIUS series typically carries UL, CSA, and CE certifications, though specific marks for this exact variant should be verified on the nameplate or certificate.

MPN
3RV1353-6BP10