Siemens 3RV1364-7AN10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1364-7AN10 SIRIUS MCCB, 100 A, 200 kA at 400 V

MPN3RV1364-7AN10

Siemens SIRIUS molded-case circuit breaker, 3RV1364-7AN10, 100 A continuous current, 200 kA breaking capacity at 400 V AC, for starter combinations, screw fixing.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1364-7AN10 — Identification
ParameterValue
SeriesSIRIUS
Product designationmolded-case circuit breaker
3RV1364-7AN10 — Electrical
ParameterValue
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)8 000 V
Number of poles3
3RV1364-7AN10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current1 000 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)200 kA
Breaking capacity at 500 V (AC)150 kA
Breaking capacity at 690 V (AC)80 kA
Short-circuit trip typeelectronic
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1364-7AN10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1364-7AN10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
3RV1364-7AN10 — Mechanical
ParameterValue
Height205 mm
Width105 mm
Depth103.5 mm
Mounting methodscrew fixing
Mounting positionany
3RV1364-7AN10 — Environmental
ParameterValue
Operating temperature-25 ... +70 °C
Storage temperature-40 ... +70 °C
Transport temperature-40 ... +70 °C
Max. installation altitude2 000 m
3RV1364-7AN10 — Specifications
ParameterValue
Design Of The Productfor starter combinations

Product details

SIRIUS 3RV1364-7AN10 — 100 A MCCB for Starter Combinations

The short-circuit trip is electronic, which gives more precise coordination with downstream contactors and overload relays compared to thermal-magnetic designs.

The breaking capacity varies by line voltage: 100 kA at 240 V AC, 200 kA at 400 V AC, 150 kA at 500 V AC, and 80 kA at 690 V AC. At 690 V, the 80 kA rating still covers most heavy industrial applications. The AC-3 operational current at 400 V is 100 A, matching the continuous rating — so the motor load and the breaker rating align without derating for typical induction motor starting duty.

Environmental and Installation Constraints

Shock resistance is 12 g for 11 ms, which is standard for industrial panel mounting. Maximum installation altitude is 2,000 m above sea level — above that, dielectric strength and current-carrying capacity derate per IEC 60947. The main and auxiliary/control circuits both use screw-type terminals, so expect to torque per the manufacturer's spec on the nameplate. The breaker accepts auxiliary switch modules, but this base unit ships with zero built-in contacts — you add what the circuit needs.

Frequently asked questions

What is the breaking capacity of 3RV1364-7AN10 at 400 V?

200 kA at 400 V AC, which is the highest rating in its voltage range and suits high-fault-capacity installations.

Where can I buy 3RV1364-7AN10?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.