Skip to main content
Siemens 3RV1383-7KN10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1383-7KN10 SIRIUS MCCB, 800 A, 100 kA at 400 V

MPN3RV1383-7KN10

Siemens SIRIUS molded-case circuit breaker, 3RV1383-7KN10, 800 A continuous, 100 kA interrupting at 400 V AC, 3-pole, electronic trip, for starter combinations, IP20 finger-safe front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1383-7KN10 — Identification
ParameterValue
SeriesSIRIUS
Product designationmolded-case circuit breaker

Electrical

3RV1383-7KN10 — Electrical
ParameterValue
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)8 000 V
Number of poles3

Protection & Tripping

3RV1383-7KN10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current8 000 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)65 kA
Breaking capacity at 690 V (AC)30 kA
Short-circuit trip typeelectronic
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1383-7KN10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1383-7KN10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side

Mechanical

3RV1383-7KN10 — Mechanical
ParameterValue
Height268 mm
Width210 mm
Depth103.5 mm
Mounting methodscrew fixing
Mounting positionany

Environmental

3RV1383-7KN10 — Environmental
ParameterValue
Operating temperature-25 ... +50 °C
Storage temperature-40 ... +70 °C
Transport temperature-40 ... +70 °C
Max. installation altitude2 000 m

Specifications

3RV1383-7KN10 — Specifications
ParameterValue
Design Of The Productfor starter combinations

Product details

What this MCCB carries

The Siemens 3RV1383-7KN10 is a SIRIUS molded-case circuit breaker (MCCB) rated for 800 A continuous current, designed specifically for starter combinations in motor control centers. Its interrupting capacity hits 100 kA at 240 V and 400 V AC, drops to 65 kA at 500 V, and holds at 30 kA at 690 V — meaning this breaker clears high-fault scenarios without upstream coordination issues in most industrial distributions. The electronic short-circuit trip gives you adjustable curves for motor starting inrush, so you're not nuisance-tripping on a 400 kW induction motor across the line.

Mounting and integration

Screw fixing to the panel backplate, any mounting position. Dimensions: 268 mm tall, 210 mm wide, 103.5 mm deep — zero clearance needed at the back or sides for heat dissipation. IP20 on the front, finger-safe touch protection. Main and control circuit terminals are screw-type; the design accepts auxiliary switch add-ons (not included as standard — zero NO, NC, or CO contacts shipped). Rated for 20 to 690 V AC-3 duty, max 15 operations per hour. Surge withstand at 8 kV. Ambient operating range -25 to +50 °C; storage and transport -40 to +70 °C. Shock rated 12g for 11 ms.

Lifecycle and sourcing reality

Substance prohibitance date of 01/08/2008 aligns with RoHS compliance requirements. No ground-fault or phase-failure detection built in — that's handled upstream or by the motor starter itself.

Frequently asked questions

Where can I buy 3RV1383-7KN10 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a quote request for current pricing and delivery lead time.

What is the interrupting capacity of 3RV1383-7KN10 at different voltages?

100 kA at 240 V and 400 V AC, 65 kA at 500 V, and 30 kA at 690 V AC — sufficient for most industrial fault-current scenarios up to 690 V.

What compliance documentation does Siemens provide for 3RV1383-7KN10?

The substance prohibitance date of 01/08/2008 indicates RoHS compliance. The MCCB carries IP20 finger-safe touch protection and surge voltage resistance rated at 8 kV.

MPN
3RV1383-7KN10