3RV1421-0CA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-0CA10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1421-0CA10 — Protection & Tripping
ParameterValue
Overload release setting range0.18 ... 0.25 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1421-0CA10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1421-0CA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1421-0CA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1421-0CA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1421-0CA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

SIRIUS 3RV1421-0CA10 — transformer-protection motor starter protector

The 96 mm depth and 97 mm height fit standard enclosure layouts, with 0 mm projection at the back or sides — no extra clearance needed behind the rail. IP20 on the front and finger-safe touch protection meet the basic panel-access requirements.

The 0.25 A continuous current rating is the load-side limit for transformer primary protection — sized for a small control transformer, not a motor. Breaking capacity of 100 kA at 400 V AC (and at 240 V, 500 V, 690 V) is unusually high for a 0.25 A device — this part is designed for high-fault-current installations where the available short-circuit current at the transformer primary exceeds typical MCCB ratings. The 6 kV surge voltage resistance confirms it handles switching transients on the line side. The 15 operations per hour maximum at AC-3 duty is a switching-life limit, not a thermal limit; for transformer protection the switching frequency is typically far lower.

Mounting and wiring integration

Accepts solid or stranded conductors: 2× (1…2.5 mm²) or 2× (2.5…6 mm²), and finely stranded with core-end processing to the same cross-sections. AWG 14–10 for the main contacts. Any mounting position is permitted — no derating for horizontal or inverted orientation. The auxiliary switch extension (Product Extension Auxiliary Switch: Yes) means a 3RV19 series auxiliary switch block can be added on the side for remote status indication or interlocking — useful when the breaker feeds a transformer whose secondary supplies critical control power.

RoHS compliance date is 01.05.2012, meeting the EU RoHS exemption timeline for industrial equipment. Shock resistance rated at 25g / 11 ms — suitable for panel mounting in machinery subject to vibration.

Frequently asked questions

Where can I buy 3RV1421-0CA10?

This part is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time.

What is 3RV1421-0CA10 used for?

It is a SIRIUS circuit breaker designed for transformer protection, rated 0.25 A continuous current with Trip Class 10 and 100 kA breaking capacity at 400 V AC.

What are the key specifications of 3RV1421-0CA10?

3-pole, 0.25 A rated current, Trip Class 10, 100 kA breaking capacity at 240-690 V AC, 690 V rated voltage, screw-type terminals, IP20 front, 45 mm width, 96 mm depth, 97 mm height, snap-on DIN rail mounting.

Will 3RV1421-0CA10 drop into a panel specified around 3RV1011-0GA10?

Both are 3-pole SIRIUS circuit breakers on the same 45 mm DIN-rail footprint with similar screw-terminal wiring, so the panel cutout and rail space are compatible. However, the 3RV1421-0CA10 is rated 0.25 A with 100 kA breaking capacity and is designed for transformer protection, while the 3RV1011-0GA10 is a standard motor-protective breaker with different current ranges and breaking capacities — verify the load-side protection requirements before substituting.

MPN
3RV1421-0CA10