Siemens 3RV1421-0EA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-0EA15 SIRIUS Circuit Breaker, 0.4 A, Class 1

MPN3RV1421-0EA15

Siemens SIRIUS transformer-protection circuit breaker, 3RV1421-0EA15, 0.4 A continuous, Trip Class 10, 100 kA breaking capacity, 45 mm wide, screw and snap-on 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1421-0EA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-0EA15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1421-0EA15 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1421-0EA15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1421-0EA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1421-0EA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1421-0EA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1421-0EA15 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

SIRIUS transformer-protection circuit breaker, 0.4 A, Class 10

The Siemens SIRIUS 3RV1421-0EA15 is a circuit breaker designed specifically for transformer protection, carrying a continuous current rating of 0.4 A and a Trip Class 10 characteristic. It provides phase failure detection and offers a symmetrical breaking capacity of 100 kA across all AC voltage levels from 240 V to 690 V, meaning it can safely interrupt fault currents up to that magnitude without upstream coordination issues. The 45 mm wide housing mounts via screw and snap-on onto a standard 35 mm DIN rail per EN 50022, fitting into a standard control-panel layout.

Trip Class 10 means the bimetal element will trip within 10 seconds at 7.2× rated current, protecting the transformer winding from sustained overload without nuisance tripping on normal inrush. The 100 kA breaking capacity at 400 V and 690 V gives the breaker enough interrupting capability to serve as the sole branch-circuit protection in most industrial panels, even on high-fault-capacity mains.

The 45 mm width and 96 mm depth fit a standard 80 mm deep enclosure with room for gland plates. Screw terminals accept solid conductors up to 2x 2.5 mm² and stranded up to 2x 6 mm². Zero clearance required at the sides or rear for heat dissipation, so adjacent breakers can be ganged without derating.

Substance prohibitance per RoHS applies from 01.05.2012. Operating temperature range is -20 to +60 °C, storage and transport from -50 to +80 °C. Shock resistance rated at 25g for 11 ms. Surge voltage resistance rated at 6 000 V.

Frequently asked questions

Where can I buy 3RV1421-0EA15 and get a price?

The 3RV1421-0EA15 is sourced and quoted to order against an RFQ. Submit a request for quote to confirm current availability and pricing — no stock or price figures are published here.

What is 3RV1421-0EA15's depth?

The depth is 96 mm, with a width of 45 mm and height of 97 mm.

What compliance documentation does this part have?

The part is RoHS compliant with a substance prohibitance date of 01.05.2012. Operating temperature range is -20 to +60 °C, storage and transport from -50 to +80 °C. Shock resistance is 25g at 11 ms, and surge voltage resistance is 6 000 V.

Will 3RV1421-0EA15 drop into a panel specified around 3RV1011-0GA10 without rewiring?

The 3RV1421-0EA15 shares the same 45 mm width and 35 mm DIN rail mounting as the 3RV1011-0GA10, so mechanical fit is identical. However, the 3RV1421-0EA15 is a transformer-protection variant with a 0.4 A continuous rating and Trip Class 10, while the 3RV1011-0GA10 is a standard motor-protection breaker with different trip curves and current ranges. Verify the load type and trip coordination before substituting — the terminal wiring scheme is the same screw-type, but the protection settings differ.

MPN