Siemens 3RV1421-0FA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-0FA10 SIRIUS Circuit Breaker, 0.5 A, Class 1

MPN3RV1421-0FA10

Siemens SIRIUS circuit breaker for transformer protection, 3RV1421-0FA10, 0.5 A continuous rated current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, 45 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1421-0FA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-0FA10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1421-0FA10 — Protection & Tripping
ParameterValue
Overload release setting range0.35 ... 0.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1421-0FA10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1421-0FA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1421-0FA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1421-0FA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1421-0FA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

SIRIUS 3RV1421-0FA10 — transformer-protection circuit breaker, 0.5 A, Class 10

Its 0.5 A continuous rated current and Class 10 trip characteristic mean it opens fast enough to protect small control transformers from sustained overloads without nuisance tripping on inrush — a common pain point when a general-purpose breaker is used instead. Rated breaking capacity holds at 100 kA across the full AC voltage range — 240 V, 400 V, 500 V, and 690 V — so it handles high-fault-current scenarios without cascading upstream. Phase-failure detection is built in, which matters for three-phase transformer banks where losing one phase can overheat the remaining windings. At 45 mm wide and 97 mm tall, it takes a single 45 mm slot in a standard panel layout. Screw terminals accept 1 to 6 mm² solid or stranded — 2x conductors per clamp — so paralleling feeds or daisy-chaining to downstream terminals is straightforward.

Depth is 96 mm — check clearance behind the DIN rail, especially in shallow enclosures. The IP20 finger-safe front means it can sit in a panel without additional shrouding, but the rear terminals are live when the breaker is on. Shock-rated to 25g / 11 ms, so it survives shipping and moderate vibration in the panel.

Frequently asked questions

Where can I buy 3RV1421-0FA10 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Submit a request for current pricing and availability — confirmed at quote time.

What is the breaking capacity of 3RV1421-0FA10?

Rated breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC.

What conductor sizes does the 3RV1421-0FA10 accept?

Screw terminals accept 2x (1 to 2.5 mm²) and 2x (2.5 to 6 mm²) solid or stranded conductors per clamp.

Does 3RV1421-0FA10 include phase-failure detection?

Yes, phase-failure detection is built in. Ground-fault detection is not included.

MPN
3RV1421-0FA10