Siemens 3RV1421-0HA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-0HA10 SIRIUS Circuit Breaker, 0.8 A, Class 1

MPN3RV1421-0HA10

Siemens SIRIUS circuit breaker, 3RV1421-0HA10, for transformer protection, 0.8 A continuous current, 100 kA breaking capacity at 400 V AC, Class 10 trip, screw-type terminals, 45 mm wide, IP20 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1421-0HA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-0HA10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1421-0HA10 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1421-0HA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1421-0HA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1421-0HA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1421-0HA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1421-0HA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

The Siemens 3RV1421-0HA10 is a SIRIUS circuit breaker for transformer protection. Rated 0.8 A continuous, it is sized for small control transformers. Breaking capacity is a flat 100 kA across the full AC voltage band: 240 V, 400 V, 500 V, and 690 V. Trip Class 10 means the bimetal trips within 10 seconds at 7.2× rated current — fast enough to protect transformer windings from sustained overload, but slow enough to ignore the 100–200 ms inrush pulse.

The 45 mm width (3 module spaces) and 96 mm depth fit standard sub-distribution boards. Solid or stranded wire: 2× (1 … 2.5 mm²) or 2× (2.5 … 6 mm²). AWG equivalent 2× (14 … 10) for the main contacts. No special tooling needed — standard Pozidriv #2. Zero clearance needed at the back or sides (0 mm backwards, 0 mm at the side), so it can be packed tight in a row. Mounting position any orientation.

Frequently asked questions

What is the closest functional second-source to 3RV1421-0HA10?

The 3RV1011-0GA10 and 3RV1011-1HA10 are fellow SIRIUS breakers with similar footprints, but the 3RV1421-0HA10 is the only one designated for transformer protection with a 0.8 A rating — the others are general-purpose motor-protective breakers with different overload curves. Verify the trip curve and current rating before substituting.

What wire sizes does 3RV1421-0HA10 accept?

Screw terminals accept solid or stranded wire: 2× (1 … 2.5 mm²) or 2× (2.5 … 6 mm²). AWG equivalent 2× (14 … 10) for the main contacts.