Skip to main content
Siemens 3RV1421-0HA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-0HA10-ZX95 SIRIUS Circuit Breaker, 0.8 A, Cl

MPN3RV1421-0HA10-ZX95

Siemens SIRIUS transformer-protection circuit breaker, 3RV1421-0HA10-ZX95, 0.8 A continuous, 100 kA breaking at 400 V, Class 10 trip, screw terminals, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1421-0HA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-0HA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1421-0HA10-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1421-0HA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1421-0HA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1421-0HA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1421-0HA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1421-0HA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

The Siemens SIRIUS 3RV1421-0HA10-ZX95 is a transformer-protection circuit breaker rated at 0.8 A continuous current with a 100 kA breaking capacity at 400 V AC — that's the same interrupting rating across 240 V through 690 V, so it clears faults up to that level without cascading upstream.

Snaps onto a 35 mm DIN rail per EN 50022 and accepts screw-type terminals on the main circuit — 2x (1–2.5 mm²) solid or stranded, or 2x (2.5–6 mm²) for heavier tails. The 45 mm wide body leaves room for adjacent breakers in a crowded panel; depth is 96 mm, height 97 mm.

Environmental and electrical margins

Surge voltage resistance is 6 000 V, and the unit withstands 25 g / 11 ms shock. Phase-failure detection is built in; ground-fault detection is not. The auxiliary switch option is present on this variant (0 factory-fitted auxiliary contacts, but the slot is there for field addition).

Frequently asked questions

How do I get pricing and availability for 3RV1421-0HA10-ZX95?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time.

What is the closest functional alternative to 3RV1421-0HA10-ZX95?

The 3RV1011-0GA10 is a similar SIRUS motor-protective circuit breaker but lacks the transformer-protection design and the 0.8 A rating — verify the trip curve and current range before substituting. The 3RV1421-0HA10-ZX95 is purpose-built for transformer primary protection with a Class 10 trip.

MPN
3RV1421-0HA10-ZX95