Siemens 3RV1421-0KA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-0KA10-ZX95 SIRIUS Circuit Breaker, 1.25 A, C

MPN3RV1421-0KA10-ZX95

Siemens SIRIUS 3RV1421-0KA10-ZX95, circuit breaker for transformer protection, 1.25 A continuous, 3-pole, Class 10, 100 kA at 400 V AC, screw terminals, IP20, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1421-0KA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-0KA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1421-0KA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1421-0KA10-ZX95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1421-0KA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1421-0KA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1421-0KA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1421-0KA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Transformer Protection Circuit Breaker, 1.25 A, Class 10

The Siemens SIRIUS 3RV1421-0KA10-ZX95 is a 3-pole circuit breaker designed specifically for transformer protection, rated at 1.25 A continuous current with a Class 10 trip characteristic. This means it coordinates with transformer inrush — the magnetic trip element allows the brief high magnetizing current on energization while the thermal bimetal protects against sustained overloads. That figure holds across the full voltage range up to 690 V AC, so this breaker can be placed upstream in a high-fault-current sub-distribution without worrying about cascading failure. Zero clearance needed at the sides or rear — 0 mm backwards and 0 mm at the side — so it packs tight in a crowded enclosure. The IP20 finger-safe front protection means you can reach into the panel without de-energizing the bus for routine visual checks.

Main circuit terminals are screw-type, accepting 2x (1... 2.5 mm²) solid or 2x (2.5... 6 mm²) solid, and the same ranges for stranded wire. For AWG, that translates to 2x (14... 10) on the main contacts. The auxiliary and control circuit uses the same screw-terminal style, so you don't need a second tool or separate terminal block for the aux switch wiring. Power dissipation is 7.25 W total in hot operating state, or 2.4 W per pole. That's low enough to skip forced ventilation in a standard IP20 enclosure as long as the ambient stays under 60 °C.

Frequently asked questions

What is 3RV1421-0KA10-ZX95's depth?

The depth is 96 mm, with a width of 45 mm and height of 97 mm.

What wire sizes does the 3RV1421-0KA10-ZX95 accept?

Solid wire: 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²). Stranded: same ranges. AWG main contacts: 2x (14... 10).

What compliance documentation does this SIRIUS breaker carry?

RoHS compliance date is 01.05.2012. The product is finger-safe (IP20 front) and mounts on DIN rail per DIN EN 50022. Touch protection against electrical shock is finger-safe.