Skip to main content
Siemens 3RV1421-0KA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-0KA15 SIRIUS Circuit Breaker, 1.25 A, CLASS

MPN3RV1421-0KA15

Siemens SIRIUS circuit breaker for transformer protection, 3RV1421-0KA15, 1.25 A continuous rating, CLASS 10 trip class, 100 kA breaking capacity up to 690 V AC, screw-type terminals, 45 mm wide, snap-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1421-0KA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-0KA15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1421-0KA15 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1421-0KA15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1421-0KA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1421-0KA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1421-0KA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1421-0KA15 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Transformer-protection circuit breaker, 1.25 A, CLASS 10

This means it handles the inrush of a transformer without nuisance tripping — CLASS 10 allows up to 10 seconds at 7.2x rated current, which covers magnetizing inrush on small to medium transformers. The 100 kA breaking capacity holds at 240 V, 400 V, 500 V, and 690 V AC, so this single part covers the full low-voltage range without derating on fault clearing. The auxiliary switch is a transverse design and the product extension allows adding auxiliary contacts later without replacing the entire unit.

Mounting and wiring — 45 mm wide, screw terminals, DIN rail

Screw-type terminals on both the main and auxiliary/control circuits. Main circuit accepts 2x (0.5 to 1.5 mm²) solid or 2x (1 to 2.5 mm²) stranded, and 2x (0.75 to 2.5 mm²) solid or 2x (2.5 to 6 mm²) stranded — covers most panel wiring up to 6 mm². AWG equivalents are 2x (14 to 10) for the main contacts. Front protection is IP20, safe for finger-probe access inside an enclosure.

Environmental limits and power dissipation

Operates from -20 °C to +60 °C, stores and transports from -50 °C to +80 °C. Shock resistance is 25g for 11 ms.

Frequently asked questions

Who supplies 3RV1421-0KA15 and how is it quoted for volume purchases?

We source this part through independent distribution channels. Submit an RFQ for current availability and volume pricing — availability and price are confirmed at quote time.

What is 3RV1421-0KA15's listed depth?

The depth is 96 mm, with a width of 45 mm and height of 97 mm.

What compliance documentation does 3RV1421-0KA15 carry?

The part meets RoHS (substance prohibition date 01.05.2012) and REACH requirements, and carries a 6 kV surge voltage resistance rating indicating IEC 60947-2 compliance.

MPN
3RV1421-0KA15