Siemens 3RV1421-1GA10-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-1GA10-0BA0 SIRIUS Circuit Breaker, 6.3 A, Tr

MPN3RV1421-1GA10-0BA0

Siemens SIRIUS 3RV1421-1GA10-0BA0, circuit breaker for transformer protection, 6.3 A rated continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, 45 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1421-1GA10-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-1GA10-0BA0 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1421-1GA10-0BA0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1421-1GA10-0BA0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)500
Switching frequency, AC-3 (max.)15 1/h
3RV1421-1GA10-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1421-1GA10-0BA0 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1421-1GA10-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1421-1GA10-0BA0 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

The Siemens 3RV1421-1GA10-0BA0 is a SIRIUS-brand circuit breaker specifically designed for transformer protection. It carries a rated continuous current of 6.3 A and a CLASS 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× rated current — fast enough to protect a transformer winding from sustained overload but coordinated to ride through inrush. Breaking capacity is 100 kA at 240 V, 400 V, and 500 V AC, dropping to 6 kA at 690 V AC. No ground-fault detection on this variant.

Zero clearance needed above or below (0 mm backwards, 0 mm at the sides), so you can pack it tight against other devices on the rail. Main circuit terminals are screw-type, accepting 2x (1…2.5 mm²) solid or 2x (2.5…6 mm²) stranded. AWG equivalents are 2x (14…10).

Environmental and electrical ratings

Operates from -50 °C to +60 °C ambient, with storage and transport range extending to -50…+80 °C. Shock-rated at 25 g for 11 ms. Power dissipation runs 7.25 W total in hot operating state (2.4 W per pole) — thermal management is straightforward in a standard IP20 enclosure. Mechanical endurance is 500 operations of the main contacts typical. Maximum switching frequency at AC-3 duty is 15 operations per hour.

Frequently asked questions

What is 3RV1421-1GA10-0BA0 used for?

It is a circuit breaker designed specifically for transformer protection, with a 6.3 A continuous rating, CLASS 10 trip, and phase failure detection. It protects transformer windings from overload and short circuits while coordinating with inrush current.

What breaking capacity does 3RV1421-1GA10-0BA0 have?

It offers 100 kA breaking capacity at 240 V, 400 V, and 500 V AC, and 6 kA at 690 V AC. The 100 kA rating at 400 V covers most industrial panel fault levels without needing upstream fusing.