Siemens 3RV1421-4AA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-4AA15 SIRIUS Circuit Breaker, 16 A, Class 10

MPN3RV1421-4AA15

Siemens SIRIUS 3RV1421-4AA15 circuit breaker for transformer protection, 16 A continuous, Class 10 trip, 690 V rated, 45 mm wide, screw and snap-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1421-4AA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-4AA15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1421-4AA15 — Protection & Tripping
ParameterValue
Overload release setting range11 ... 16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1421-4AA15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1421-4AA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1421-4AA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1421-4AA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1421-4AA15 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

The Siemens 3RV1421-4AA15 is a SIRIUS circuit breaker specifically designed for transformer protection — meaning its trip curve and thermal memory are tuned to handle the inrush and sustained overload profile of a transformer primary, not a motor start. Breaking capacity is 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC — so in a 400 V panel it handles high-fault-current scenarios without cascading upstream. No ground fault detection on this variant.

Width is 45 mm, height 97 mm, depth 96 mm — fits standard panel layout with no side clearance needed (0 mm backwards and at the side). Any mounting position allowed. Main circuit terminals accept solid 2x (0.5–1.5 mm²) and 2x (0.75–2.5 mm²), stranded 2x (1–2.5 mm²) and 2x (2.5–6 mm²), or AWG 2x (14–10). Auxiliary and control circuit terminals are also screw type. The auxiliary switch is transverse design and field-addable.

RoHS compliance date is 01.05.2012.

Frequently asked questions

What is the continuous current rating and trip class?

Rated 16 A continuous with a Class 10 trip characteristic, designed for transformer protection.

Does it detect phase failure?

Yes, phase failure detection is built in. No ground fault detection on this variant.

MPN
3RV1421-4AA15