Skip to main content
Siemens 3RV1421-4AA38-1KT0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1421-4AA38-1KT0 SIRIUS Circuit Breaker, 16 A, Cla

MPN3RV1421-4AA38-1KT0

Siemens SIRIUS 3RV1421-4AA38-1KT0, circuit breaker for transformer protection, 16 A, Class 10, 50 kA breaking capacity at 400 V AC, screw terminals, IP20 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1421-4AA38-1KT0 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1421-4AA38-1KT0 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1421-4AA38-1KT0 — Protection & Tripping
ParameterValue
Overload release setting range11 ... 16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1421-4AA38-1KT0 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1421-4AA38-1KT0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (24 ... 14)
3RV1421-4AA38-1KT0 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1421-4AA38-1KT0 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1421-4AA38-1KT0 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

The Siemens SIRIUS 3RV1421-4AA38-1KT0 is a circuit breaker specifically designed for transformer protection — not a general-purpose motor-protective breaker, but one tuned to handle the inrush and thermal characteristics of transformers. The 45 mm width means it takes up a single modular space in a standard panel layout.

Rated at 16 A continuous current, this breaker handles transformer loads up to that steady-state value. The Class 10 trip characteristic means it will hold through the high inrush of an energizing transformer (typically 8–12x rated for 0.1–0.5 s) but still trip quickly on a hard fault — critical for protecting both the transformer and downstream wiring. Breaking capacity is the real selector here: 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. No ground-fault detection on this variant, so if that's required, you'd need an add-on module or a different base unit. The auxiliary switch is transverse-mounted, and its ratings are 1 A at 24 V, 0.15 A at 60 V, and 0.5 A at 230 V — enough for signaling to a PLC or indicator lamp.

Mounting and Environment

Zero clearance needed at the sides or back — 0 mm spacing — so you can pack modules tight in the enclosure. Shock-rated at 25g for 11 ms — fine for most industrial environments including machine-mounted panels.

Frequently asked questions

What is the breaking capacity of 3RV1421-4AA38-1KT0 at 400 V?

50 kA at 400 V AC, which covers most industrial distribution panel fault-current levels without requiring an upstream current-limiting fuse.

Where can I buy 3RV1421-4AA38-1KT0 and how is it quoted?

We source this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — just send the RFQ.

What compliance documentation is available for this breaker?

The part is RoHS-compliant with a substance prohibition date of 01.05.2012. Standard Siemens SIRIUS documentation includes CE, UL, and CSA certifications as part of the series listing.

MPN
3RV1421-4AA38-1KT0