Skip to main content
Siemens 3RV1431-4AA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1431-4AA10 SIRIUS Circuit Breaker, 16 A, Class 10

MPN3RV1431-4AA10

Siemens SIRIUS circuit breaker for transformer protection, 3RV1431-4AA10, 16 A continuous, Class 10 trip, 50 kA breaking capacity at 400 VAC, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1431-4AA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1431-4AA10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W
3RV1431-4AA10 — Protection & Tripping
ParameterValue
Overload release setting range11 ... 16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1431-4AA10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1431-4AA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1431-4AA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1431-4AA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1431-4AA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Breaking capacity: 100 kA at 240 VAC, 50 kA at 400 VAC, 12 kA at 500 VAC, 5 kA at 690 VAC. Three-pole, screw-type box terminals for the main circuit accepting 2x 0.75…16 mm² solid or 2x 0.75…25 mm² stranded, with a single conductor up to 35 mm². Finger-safe touch protection — no live metal exposed at the front, so panel builders can work near it without additional shrouding. Zero clearance needed at the sides or rear, so it packs tight in a crowded enclosure. IP20 on the front — fine for a dry indoor panel; not rated for washdown.

Lifecycle and sourcing — still in active production

Lifecycle stage is current — Siemens still manufactures this order code. Substance prohibitance date of 07/01/2006 indicates RoHS compliance for that cutoff.

Integration into a panel — DIN rail fit and wiring

Any mounting position accepted, so it can go sideways or upside-down in a tight sub-panel. Depth 149 mm, width 55 mm, height 140 mm. Auxiliary switch optional — the breaker accepts a snap-on auxiliary contact block if you need remote status feedback. No ground-fault detection built in; phase-failure detection is included.

Environmental and mechanical limits

Shock rated at 25 g for 11 ms — survives typical panel vibration and occasional drops during installation. Power dissipation 14.5 W in hot operating state, or 4.8 W per pole. That heat needs to be considered in a sealed enclosure with multiple breakers ganged together. Surge voltage resistance rated at 6 000 V — coordinates with standard industrial SPDs for impulse withstand.

Frequently asked questions

What is the 3RV1431-4AA10's depth?

Depth is 149 mm. That's the critical dimension for shallow enclosure clearance.

What solid wire size does the 3RV1431-4AA10 accept?

The main circuit terminals accept 2x 0.75…16 mm² solid. Stranded goes up to 2x 25 mm² or 1x 35 mm².

Will the 3RV1431-4AA10 drop into a panel specified around the 3RV6021-4DA10?

Both mount on 35 mm DIN rail per DIN EN 50022 and share the same three-pole form factor. The 3RV1431-4AA10 is a transformer-protection breaker; the 3RV6021-4DA10 is a motor-protection variant. Check the trip curve and continuous rating against your load before substituting — the mechanical footprint is compatible, but the protective function differs.

What compliance documentation does Siemens provide for the 3RV1431-4AA10?

The part carries a substance prohibitance date of 07/01/2006, indicating RoHS compliance per the original EU directive. Finger-safe touch protection and IP20 front protection are design features, not third-party certifications. For full UL, CSA, or IEC declarations, request the manufacturer's declaration of conformity with your RFQ.

MPN