Siemens 3RV1431-4BA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1431-4BA10 SIRIUS Circuit Breaker, Transformer Pr

MPN3RV1431-4BA10

Siemens SIRIUS, circuit breaker for transformer protection, 3RV1431-4BA10, 20 A continuous, Class 10 trip, 100 kA breaking at 240 V AC, screw terminals, IP20 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1431-4BA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1431-4BA10 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W
3RV1431-4BA10 — Protection & Tripping
ParameterValue
Overload release setting range14 ... 20 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1431-4BA10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1431-4BA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1431-4BA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1431-4BA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1431-4BA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Breaking capacity is 100 kA at 240 V AC, 50 kA at 400 V AC, 12 kA at 500 V AC, and 5 kA at 690 V AC — so on a 400 V supply it clears a 50 kA prospective fault without upstream fuses needing to coordinate.

Main circuit terminals accept solid 2x (0.75…16 mm²) or stranded 2x (0.75…25 mm²) with a single conductor up to 35 mm² — enough for the 20 A feed without a separate terminal block.

For a BOM line that needs a transformer-protection breaker at 20 A, Class 10, with 50 kA breaking at 400 V, the 3RV1431-4BA10 is the current-production choice — no need to stockpile or search surplus.

Frequently asked questions

Does the 3RV1431-4BA10 have RoHS compliance documentation?

The part carries a substance prohibition date of 07/01/2006, which aligns with RoHS compliance — standard Siemens documentation is available.