Siemens 3RV1431-4FA10-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1431-4FA10-0BA0 SIRIUS Circuit Breaker, 40 A, Cla

MPN3RV1431-4FA10-0BA0

Siemens SIRIUS circuit breaker for transformer protection, 3RV1431-4FA10-0BA0, 40 A continuous, Class 10 trip, 50 kA at 400 V AC, screw terminals, IP20 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1431-4FA10-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1431-4FA10-0BA0 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)29 W
Power loss, per pole (AC, hot)9.7 W
3RV1431-4FA10-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range28 ... 40 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1431-4FA10-0BA0 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1431-4FA10-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1431-4FA10-0BA0 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1431-4FA10-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1431-4FA10-0BA0 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Breaking capacity is rated at 50 kA at 400 V AC, 100 kA at 240 V, 10 kA at 500 V, and 4 kA at 690 V — covering the common industrial distribution voltages.

The footprint is 55 mm wide × 140 mm high × 149 mm deep, with zero clearance required at the back or sides — so it fits tight against adjacent components in a crowded panel. Terminals accept solid conductors 2× (0.75 … 16 mm²) and stranded 2× (0.75 … 25 mm²) or 1× (0.75 … 35 mm²). The main circuit uses screw-type box terminals; auxiliary and control circuits also use screw terminals. AWG equivalents are 2× (18 … 2) solid and 1× (18 … 2) stranded.

Substance prohibition date is 07/01/2006 — consistent with RoHS compliance. The front face carries IP20 finger-safe touch protection.

Frequently asked questions

What is the breaking capacity of 3RV1431-4FA10-0BA0 at 400 V?

50 kA at 400 V AC.

Where can I buy 3RV1431-4FA10-0BA0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV1431-4FA10-0BA0