Siemens 3RV1611-0BD10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1611-0BD10-ZI45 SIRIUS Circuit Breaker, Fuse Moni

MPN3RV1611-0BD10-ZI45

Siemens SIRIUS circuit breaker, size S00, for fuse monitoring, screw-type terminals, A-release 0.2 A, N-release 1.2 A, IP20, DIN rail mount, 3RV1611-0BD10-ZI45.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1611-0BD10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1611-0BD10-ZI45 — Electrical
ParameterValue
Rated operational current (Ie)0.2 A
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1611-0BD10-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
3RV1611-0BD10-ZI45 — Mechanical
ParameterValue
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV1611-0BD10-ZI45 — Specifications
ParameterValue
Design Of The Productfor fuse monitoring

Product details

The Siemens 3RV1611-0BD10-ZI45 is a SIRIUS circuit breaker in size S00, designed specifically for fuse monitoring rather than motor protection. It carries a rated operational current of 0.2 A with an A-release and a 1.2 A N-release, and connects via screw-type terminals at the top and bottom.

Clearance and mounting

Clearance requirements: 20 mm upwards, 20 mm downwards, 9 mm to the side, and zero forwards or backwards — tight panel fit, but the side gap is the one to watch when packing multiple units side-by-side.

Power dissipation

At AC in hot operating state the unit dissipates 5.5 W total, or 1.8 W per pole.

Frequently asked questions

What is 3RV1611-0BD10-ZI45 used for?

It is a SIRIUS circuit breaker designed for fuse monitoring, not motor protection — the 0.2 A A-release and 1.2 A N-release are set up to detect a blown fuse and signal that condition, typically in a control circuit.

What clearance does this circuit breaker need in the panel?

It needs 20 mm upwards, 20 mm downwards, and 9 mm to the side; zero clearance forwards or backwards. The side gap is the tightest dimension when ganging multiple units.

Where can I buy 3RV1611-0BD10-ZI45?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN