ParameterValue
SeriesSIRIUS
Product designationshunt release
Frame sizeS00, S0, S2, S3
3RV1902-1DB0 — Electrical
ParameterValue
Rated insulation voltage (Ui), pollution degree 3690 V
3RV1902-1DB0 — Mechanical
ParameterValue
Height90 mm
Width18.5 mm
Depth68 mm
Mounting methodsnap-on mounting
3RV1902-1DB0 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C

Product details

The Siemens SIRIUS 3RV1902-1DB0 is a shunt release for motor circuit breakers, designed to trip the breaker remotely when its control coil is energized. It accepts a control supply of 20-24 V AC at 50/60 Hz, with a 100% duty cycle at 24 V and a 5-second ON period for the extended 20-70 V AC or DC range. This is a phased-out product; the official successor is the SIRIUS 3RV2902-1DB0. The IP20 finger-safe front (IEC 60529) protects against accidental contact with live parts from the front — standard for enclosed panel installations.

For a BOM line that still specifies the 3RV1902-1DB0, the 3RV2902-1DB0 is the direct drop-in replacement from the same SIRIUS family, sharing the same function and footprint. No rewiring or panel modification should be needed when substituting the successor.

At 18.5 mm wide and 68 mm deep, this shunt release fits circuit breaker frames S00, S0, S2, and S3. Rated insulation voltage 690 V with pollution degree 3. The AC control coil draws power only during the trip pulse.

Frequently asked questions

Will the 3RV1902-1DB0 fit a panel designed for the 3RV1011-0GA10?

No, not without rewiring or adapter hardware. The 3RV1902-1DB0 is a shunt release accessory (18.5 mm wide, snap-on), while the 3RV1011-0GA10 is a complete motor circuit breaker (45 mm wide, screw and snap-on). They serve different functions and have different footprints.

What is the control voltage range for the 3RV1902-1DB0?

Rated control supply voltage is 20-24 V AC at 50/60 Hz (100% ON period). For extended tripping, the range is 20-70 V AC or DC with a 5-second ON period.