Skip to main content
Siemens 3RV1902-1DP00-0FJ0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1902-1DP00-0FJ0 Shunt Trip, 210-240V AC, Size S00

MPN3RV1902-1DP00-0FJ0

Siemens 3RV1902-1DP00-0FJ0, shunt trip for 3RV2 circuit breakers, 210-240V AC 50/60Hz, 100% ED, size S00 through S3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3RV1902-1DP00-0FJ0 is a shunt trip accessory for the 3RV2 series of circuit breakers, sized S00 through S3. The coil also accepts an extended range of 190-330V AC for a 5-second duty cycle (CDF or ED), covering brownout or generator-sourced control power without dropping out.

The 210-240V AC nominal coil voltage matches standard European and North American control transformer secondaries. The 100% ED rating means the coil can be energized continuously without overheating — important for applications where the shunt trip must remain armed for extended periods, such as emergency-stop circuits or remote-disconnect panels. The extended 190-330V AC range at 5-second duty covers momentary trip commands from a wider voltage band, useful when the control supply is unregulated or shared with motor starting loads. The size S00-S3 designation means this shunt trip mounts directly onto the 3RV2 breaker family across the full frame range. No adapter plate or wiring harness change is needed when swapping between a size S00 and an S3 breaker — the accessory footprint is common. Panel integration is straightforward: the trip unit clips onto the breaker side, and the two coil leads terminate at the control terminal block.

Deployment Context

This shunt trip is used in motor control centers and distribution panels where a remote signal (E-stop, PLC output, fire-alarm relay) must open the breaker without an operator at the handle.

Frequently asked questions

Where can I buy the 3RV1902-1DP00-0FJ0 and how is it quoted?

The 3RV1902-1DP00-0FJ0 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What voltage range does this shunt trip accept?

The nominal coil voltage is 210-240V AC at 50/60 Hz for continuous duty. It also accepts 190-330V AC for a 5-second duty cycle.

What breaker sizes does the 3RV1902-1DP00-0FJ0 fit?

It fits the entire 3RV2 breaker family from size S00 through S3.

MPN
3RV1902-1DP00-0FJ0