Skip to main content
Siemens 3RV1915-5A — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1915-5A SIRIUS 3-Phase Supply Terminal, 63 A, S00

MPN3RV1915-5A
Active

Siemens SIRIUS 3-phase supply terminal, 3RV1915-5A, 63 A ampacity, 690 V insulation, screw-type terminals, for circuit breaker sizes S00 and S0.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1915-5A — Identification
ParameterValue
SeriesSIRIUS
Product designation3-phase supply terminal
Frame sizeS00, S0
3RV1915-5A — Electrical
ParameterValue
Rated insulation voltage (Ui), pollution degree 3690 V
3RV1915-5A — Connections
ParameterValue
Conductor cross-section, solid / stranded2.5 ... 25 mm²
Conductor cross-section, finely stranded with ferrule4 ... 16 mm²
3RV1915-5A — Mechanical
ParameterValue
Height24 mm
Width44 mm
Depth25 mm
3RV1915-5A — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
3RV1915-5A — Other specifications
ParameterValue
Solid1x (2.5 ... 25 mm²)
Stranded2.5 ... 25 mm²
Ampacity maximum63 A
Substance prohibitance07/01/2006
For AWG cables for main contacts1x (12 ... 4)
Type of electrical connection for main current circuitscrew-type terminals
AWG number as coded connectable conductor cross section for main contacts12 ... 4

Product details

The Siemens 3RV1915-5A is a SIRIUS 3-phase supply terminal that feeds three-phase busbars into circuit breaker sizes S00 and S0 from the top, using pin-shaped connections. It accepts solid or stranded conductors from 2.5 to 25 mm² (AWG 12 to 4) and is rated for a maximum ampacity of 63 A, with an insulation voltage of 690 V AC at pollution degree 3. The screw-type terminals are sized for the main current circuit of the breaker, making this a panel-integration component rather than a standalone protective device.

Physical fit and wiring constraints

The terminal measures 44 mm wide by 24 mm high by 25 mm deep — a compact footprint that sits directly on the busbar feed point of the S00 or S0 breaker. The 25 mm depth is the key dimension for panel clearance: it projects less than a typical contactor or breaker depth, so it fits into shallow gland-plate zones or behind a DIN-rail mounted assembly. Conductor range covers 2.5 to 25 mm² solid or stranded, and 4 to 16 mm² finely stranded with ferrule. The single-conductor entry per phase (1x) means you cannot double-feed the same terminal; plan for a separate distribution block if you need to split the feed.

Frequently asked questions

What is the ampacity rating of 3RV1915-5A?

The maximum ampacity is 63 A. This is the continuous current rating for the terminal block itself, not the breaker it feeds — the connected circuit breaker's rating must be selected based on the load.

What wire sizes does 3RV1915-5A accept?

It accepts solid or stranded conductors from 2.5 to 25 mm² (AWG 12 to 4) for the main current circuit, and finely stranded conductors with ferrule from 4 to 16 mm². The terminal accepts a single conductor per phase (1x).

Where can I buy 3RV1915-5A and how is it quoted?

The part is sourced and quoted to order against an RFQ through independent industrial-automation distribution channels. Availability and current pricing are confirmed at quote time; no stock count or price is published here.

Does 3RV1915-5A replace a motor-protective circuit breaker like 3RV1011-0GA10?

No. The 3RV1915-5A is a 3-phase supply terminal for busbar connection to S00/S0 breakers. It has no overcurrent protection, no switching function, and no adjustable trip settings. The 3RV1011-0GA10 is a motor-protective circuit breaker with thermal/magnetic releases. The terminal feeds the breaker; it does not substitute for it.

MPN
3RV1915-5A