Siemens 3RV2011-0AA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0AA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV2011-0AA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, Size S00, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw and snap-on 35 mm DIN rail mounting, 3RV2011-0AA10-ZW97.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2011-0AA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-0AA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)0.16 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2011-0AA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.11 ... 0.16 A
Instantaneous short-circuit trip current2.1 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-0AA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-0AA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2011-0AA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-0AA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-0AA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker, Size S00, Class 10 — what that means for your panel

Breaking capacity is 100 kA at 400 V AC and 500 V AC, and 100 kA at 690 V AC — that's a high-interrupting rating for a Size S00 device, meaning it can clear faults on high-capacity industrial networks without needing upstream fuses or a larger frame. Ground fault detection is not included, so if you need that, you'll add a separate ground-fault module or relay.

How this breaker differs from the base 3RV2011-0AA10

The -ZW97 suffix indicates a special version — a customer-specific variant or a factory-customized configuration. Mechanically and electrically it shares the same Size S00 frame, Trip Class 10, and 100 kA breaking capacity as the standard 3RV2011-0AA10. The screw-type terminals accept 2× 0.75–2.5 mm² solid/stranded or 2× 4 mm², same as the base part. If your panel was wired for the 3RV2011-0AA10, the -ZW97 drops in without rewiring — same footprint, same mounting, same terminal layout.

Clearance around the breaker: 50 mm above, 50 mm below, 30 mm to the side — no extra space needed front or back.

Frequently asked questions

Will 3RV2011-0AA10-ZW97 drop into a panel specified for 3RV2011-0AA10?

Yes — same Size S00 frame, same 45 mm width, same screw-type terminals, same Trip Class 10. No rewiring needed.

MPN
3RV2011-0AA10-ZW97