Skip to main content
Siemens 3RV2011-0BA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0BA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-0BA10
Active

Siemens SIRIUS motor protection circuit breaker, size S00, 3RV2011-0BA10, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on 35 mm DIN rail mount.

StockContact for availability
Lead timeCall for availability wk
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0BA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0BA10 — Electrical
ParameterValue
Rated operational current (Ie)0.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0BA10 — Protection & Tripping
ParameterValue
Overload release setting range0.14 ... 0.2 A
Instantaneous short-circuit trip current2.6 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0BA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0BA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12

Mechanical

3RV2011-0BA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0BA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0BA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2011-0BA10 is a SIRUS motor protection circuit breaker in the size S00 frame, designed for motor protection with Trip Class 10 and phase failure detection. It delivers 100 kA breaking capacity at 400 V AC, sized for direct motor starting duty up to 15 operations per hour at AC-3 maximum. Screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Current lifecycle stage — no obsolescence notice on record.

Compared to the sibling 3RV2011-0BA20, the -0BA10 shares the same size S00 frame, same DIN rail footprint, and same 100 kA breaking capacity at 400 V. The deciding difference is the trip class: the -0BA10 is Class 10, while the -0BA20 is Class 20. For motor protection, Class 10 trips faster on overload — within 10 seconds at 7.2× rated current — which matters for high-inertia loads or motors with short thermal time constants. Both parts mount identically and accept the same screw-type terminals (M3 main contacts, 2x 0.75–2.5 mm² solid/stranded).

Mounts on 35 mm DIN rail per DIN EN 60715, screw and snap-on. Any mounting position. Clearance: 50 mm upward and downward, 30 mm at the side, zero forward or backward. Screw-type terminals for the main circuit (M3), accepts 2x 0.75–2.5 mm² or 2x 4 mm² solid/stranded. Screwdriver shaft diameter 5–6 mm, Pozidriv size 2 tip. Operating temperature -20 to +60 °C; storage/transport -50 to +80 °C.

Frequently asked questions

Will the 3RV2011-0BA10 drop into a panel specified for the 3RV2011-0BA20?

Yes. Both are size S00, same 45 mm width, same 97 mm depth and height, same screw and snap-on DIN rail mount. No rewiring needed — the terminal layout and screw-type connections are identical.

What compliance documentation does Siemens provide for the 3RV2011-0BA10?

As a SIRIUS motor protection circuit breaker, it carries the usual Siemens declarations for RoHS, REACH, and applicable IEC/EN standards. Specific certification details (UL, CSA, CE) should be confirmed from the manufacturer's current documentation or at quote time.

MPN
3RV2011-0BA10