Skip to main content
Siemens 3RV2011-0BA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0BA10-ZW97 SIRIUS Motor Protection CB, Class

MPN3RV2011-0BA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-0BA10-ZW97, Size S00, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw-type terminals, screw and snap-on mounting on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0BA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0BA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)0.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0BA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.14 ... 0.2 A
Instantaneous short-circuit trip current2.6 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0BA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0BA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-0BA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0BA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0BA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker, Size S00, Class 10

The Siemens 3RV2011-0BA10-ZW97 is a SIRIUS motor protection circuit breaker in the Size S00 frame, designed for motor protection with Trip Class 10 — meaning it will trip within 10 seconds at 7.2× the thermal setting, fast enough to protect standard induction motors from locked-rotor heating without nuisance tripping on normal starts. Rated breaking capacity is 100 kA at 400 V AC (also 100 kA at 240 V, 500 V, and 690 V AC), giving substantial SCCR headroom for most industrial panel designs without requiring upstream current-limiting fuses. Built-in phase failure detection trips the breaker if one phase is lost — a common cause of single-phasing motor burnouts on delta-connected loads. Mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715; mounting position is any, which simplifies panel layout in tight enclosures.

Panel integration and wiring

Occupies 45 mm width on the DIN rail, with a depth of 97 mm and height of 97 mm — a compact footprint for the Size S00 frame. Clearance requirements: 50 mm above and below, 30 mm at the sides, zero forward or backward clearance needed. Main circuit terminals are screw-type, accepting 2×(0.75…2.5 mm²) solid/stranded or 2×4 mm². Screwdriver shaft diameter 5 to 6 mm, Pozidriv size 2 tip. Operating temperature range -20 to +60 °C; storage and transport -50 to +80 °C.

Frequently asked questions

Does 3RV2011-0BA10-ZW97 include phase failure detection?

Yes, phase failure detection is built in — the breaker trips on loss of any phase to prevent single-phasing motor damage.

MPN
3RV2011-0BA10-ZW97