Siemens 3RV2011-0BA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0BA25 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-0BA25
Active

Siemens SIRIUS, motor protection circuit breaker, 3RV2011-0BA25, Trip Class 10, 100 kA breaking capacity at 400 V AC, phase failure detection, spring-loaded terminals, screw and snap-on mounting on 35 mm DIN rail.

$35.56Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2011-0BA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-0BA25 — Electrical
ParameterValue
Rated operational current (Ie)0.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2011-0BA25 — Protection & Tripping
ParameterValue
Overload release setting range0.14 ... 0.2 A
Instantaneous short-circuit trip current2.6 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-0BA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-0BA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2011-0BA25 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-0BA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-0BA25 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

It's a current-production part, still actively specified into new panels. Trip Class 10. Phase failure detection is included. That's enough for most industrial distribution panels fed by a transformer of 1000 kVA or less.

Width is 45 mm. Spring-loaded terminals accept 2 × (0.5 to 2.5 mm²) solid or stranded copper. Clearance: 50 mm needed above and below for arc venting and cable bending; 30 mm at the sides. Zero clearance forward or backward — you can butt it against other devices on the rail.

Environmental range

This is a current-production part.

MPN
3RV2011-0BA25