Siemens 3RV2011-0CA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0CA20-ZX95 SIRIUS Motor Circuit Breaker, Cla

MPN3RV2011-0CA20-ZX95
Active

Siemens SIRIUS 3RV2011-0CA20-ZX95 motor protection circuit breaker, size S00, Class 10 trip, 100 kA breaking capacity at 400 V AC, phase failure detection, screw and snap-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0CA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0CA20-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)0.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0CA20-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.18 ... 0.25 A
Instantaneous short-circuit trip current3.3 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0CA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0CA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)

Mechanical

3RV2011-0CA20-ZX95 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0CA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0CA20-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and what it does

The Siemens SIRIUS 3RV2011-0CA20-ZX95 is a motor protection circuit breaker in the size S00 frame, designed to protect three-phase induction motors against overload, short-circuit, and phase failure. Its Class 10 trip characteristic means it will disconnect within 10 seconds at 7.2× the thermal setting — fast enough to protect standard IEC motor windings during a locked-rotor event. The 100 kA breaking capacity at 400 V AC is the figure that governs fault-clearing: it can safely interrupt a bolted short-circuit up to that level without welding contacts or cascading upstream, which is what makes it suitable for high-fault-capacity industrial panels. Phase failure detection is built in, so a lost phase on the line side will trip the breaker rather than letting the motor single-phase and overheat.

Mounting and panel fit

Mounts via screw or snap-on onto 35 mm standard DIN rail per DIN EN 60715. The 45 mm width and 97 mm depth mean it occupies a single 45 mm module on the rail — that's another SKU that fits the same slot as the standard S00 frame breakers. Clearance requirements: 50 mm above and below, 30 mm at the sides, and zero forward or backward clearance needed (–,). Any mounting position is acceptable. Terminals accept 2× 0.5 to 4 mm² solid or stranded wire.

Frequently asked questions

How do I get current pricing and availability for 3RV2011-0CA20-ZX95?

Submit an RFQ through this listing. Pricing and stock levels are confirmed at quote time through independent distribution channels.

Will 3RV2011-0CA20-ZX95 drop into a panel specified around 3RV2011-0BA20 without rewiring?

Both are size S00 frame breakers on the same 45 mm DIN-rail footprint with the same terminal wire range (2× 0.5–4 mm²), so the mechanical fit and wiring are identical. The difference is in the trip curve and accessories — verify the thermal setting range matches your motor FLA before swapping.

What is 3RV2011-0CA20-ZX95's listed depth?

97 mm.

What is 3RV2011-0CA20-ZX95's listed width?

45 mm.

MPN
3RV2011-0CA20-ZX95