Siemens 3RV2011-0DA25-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0DA25-ZW96 SIRIUS Motor Circuit Breaker, 0.3

MPN3RV2011-0DA25-ZW96
Active

Siemens SIRIUS 3RV2011-0DA25-ZW96 motor protection circuit breaker, size S00, CLASS 10, 0.32 A, 100 kA breaking capacity, spring-type terminals, with transverse auxiliary switches 1 NO + 1 NC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0DA25-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker

Electrical

3RV2011-0DA25-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)0.32 A
Rated voltage20 ... 690 V

Protection & Tripping

3RV2011-0DA25-ZW96 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current4.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA

Specifications

3RV2011-0DA25-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Other specifications

3RV2011-0DA25-ZW96 — Other specifications
ParameterValue
At 400 V rated value100 kA
At 500 V rated value100 kA
Substance prohibitance10/01/2009

Product details

The Siemens SIRIUS 3RV2011-0DA25-ZW96 is a motor protection circuit breaker in size S00, designed to protect a motor branch circuit against overload and short-circuit in a single device. It carries a CLASS 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× the thermal setting — the standard for protecting standard induction motors during start-up without nuisance tripping on normal acceleration. Rated operational current is 0.32 A, with an adjustable thermal overload release range that covers the motor full-load current. The magnetic short-circuit release responds at 4.2 A, providing instantaneous protection against bolted faults. Breaking capacity is a flat 100 kA across the full voltage range from 240 V through 690 V AC, so it clears high-fault-current events without cascading upstream — a key spec for panels with high available fault current. Termination is via spring-type terminals on both main and auxiliary circuits, which speeds panel wiring and eliminates the need for periodic screw-torque checks. The breaker ships with factory-installed transverse auxiliary switches (1 NO + 1 NC) for remote status indication or interlocking. Snap-on mounting onto 35 mm DIN rail per EN 60715 is standard for the S00 frame.

Fit and integration notes

The S00 frame shares the same 45 mm width and 97 mm depth as the standard 3RV2011 base variants. It snaps onto 35 mm DIN rail and occupies the same panel footprint as the screw-terminal versions (3RV2011-0AA10) or ring-lug version (3RV2011-0AA40). The spring-terminal variant (this one) differs only in the connection method — no change to mounting, spacing, or auxiliary wiring layout. Phase failure detection is built in, so the breaker will trip on loss of one phase — required for motor protection under IEC 60947-4-1. The handle provides a visible break position for lockout/tagout. Side-by-side mounting is zero-gap on both sides, saving rail space in dense panels.

Frequently asked questions

What is the trip class and what does it mean?

CLASS 10 means the overload relay will trip within 10 seconds at 7.2× the current setting. This is the standard trip class for protecting standard three-phase induction motors during direct-on-line starting.

What is the breaking capacity of this breaker?

100 kA at all AC voltages from 240 V through 690 V. This flat high-breaking-capacity rating means it can be used in high-fault-current panels without needing upstream current-limiting fuses.

Will 3RV2011-0DA25-ZW96 drop into a panel specified for 3RV2011-0BA20?

Yes, same S00 frame, same 45 mm width, same DIN-rail mounting. The only difference is the connection method: this one uses spring terminals, while the 0BA20 uses screw terminals. Panel cutouts and auxiliary wiring layout are identical.