Siemens 3RV2011-0EA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0EA20-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-0EA20-ZX95
Active

Siemens SIRIUS, motor protection circuit breaker, 3RV2011-0EA20-ZX95, Size S00, Trip Class 10, 100 kA breaking capacity at 400 V AC, spring-loaded terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0EA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0EA20-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0EA20-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Instantaneous short-circuit trip current5.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0EA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0EA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)

Mechanical

3RV2011-0EA20-ZX95 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0EA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0EA20-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and what it does

The Siemens SIRIUS 3RV2011-0EA20-ZX95 is a motor protection circuit breaker in Size S00 — 45 mm wide, 97 mm deep, 106 mm tall. It mounts on a 35 mm DIN rail and has Trip Class 10. The breaker carries a 100 kA breaking capacity at 400 V AC, and the same rating holds at 240 V, 500 V, and 690 V AC. That's a serious interrupting rating — it can clear a fault up to 100,000 amps without welding its contacts or venting arc gas into the panel. For a motor control center or a distribution board fed by a large transformer, this avoids having to coordinate upstream fuses or a bigger breaker for every branch. It also includes phase failure detection, so if one leg of a three-phase supply drops, the breaker trips rather than letting the motor single-phase and burn up. The main circuit connects via spring-loaded terminals, which speeds up wiring in a panel — no screw tightening, just strip and push.

Sizing and selection reality

The breaker is rated for motor protection, but the evidence shows a 0.1 kW rating at 230 V and a 0.4 A rating at 480 V and 600 V. That's a small motor — fractional horsepower, a coolant pump, a small fan, or a conveyor drive under a kilowatt. The AC-3 maximum operating voltage is 690 V, and the maximum switching frequency is 15 operations per hour for AC-3 and AC-3e duty. That's not a high-cycling application; it's a run-of-the-mill motor start once every four minutes or so. Mounting position is any orientation, which helps in tight enclosures. The clearance distances are 50 mm upwards and downwards, 30 mm to the side, and zero forwards or backwards. That's the space needed for arc flash venting and heat dissipation — don't cram it against the panel wall or another device without those gaps. Operating temperature range is -20 to +60 °C, storage and transport from -50 to +80 °C. If this breaker lives in a non-conditioned cabinet next to a hot motor or a furnace, the -20 to +60 °C window covers most industrial environments short of a foundry floor.

How it compares to the 3RV2011-0BA20

A buyer with a panel designed for the 3RV2011-0BA20: the -0EA20-ZX95 has the same Size S00 footprint, 45 mm width, DIN-rail mounting, and spring-loaded terminals. It will fit without rewiring, but verify the overload setting matches motor FLA.

Frequently asked questions

Will the 3RV2011-0EA20-ZX95 fit a panel designed for 3RV2011-0BA20?

Yes, both breakers share the same Size S00 footprint (45 mm wide, 97 mm deep, 106 mm tall) and the same DIN-rail mounting with spring-loaded terminals. The -ZX95 suffix indicates a special variant, but the mechanical fit is identical.

MPN
3RV2011-0EA20-ZX95