Skip to main content
Siemens 3RV2011-0FA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0FA10 SIRIUS Motor Protection Breaker, S00

MPN3RV2011-0FA10
Active

Siemens SIRIUS 3RV2011-0FA10 motor protection circuit breaker, size S00, 45 mm wide, 97 mm deep, trip class 10, 100 kA breaking capacity at 400 V, screw and snap-on DIN rail mounting.

$171.76Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2011-0FA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-0FA10 — Electrical
ParameterValue
Rated operational current (Ie)0.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2011-0FA10 — Protection & Tripping
ParameterValue
Overload release setting range0.35 ... 0.5 A
Instantaneous short-circuit trip current6.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-0FA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-0FA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2011-0FA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-0FA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-0FA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Siemens 3RV2011-0FA10: SIRIUS motor protection circuit breaker, size S00, for overload and short-circuit protection. Rated breaking capacity of 100 kA, covering typical industrial supply levels. Trip class 10 provides fast response under locked-rotor conditions, suitable for standard induction motors. The integrated phase failure detection adds protection against single-phasing.

Any mounting position is permitted. Width of 45 mm leaves room for adjacent devices; depth at 97 mm fits standard enclosures. Minimum clearances: 50 mm upward and downward, 30 mm at the sides. The main circuit connecting terminals are screw-type, accepting 2 x (0.75 to 2.5 mm²) or 2 x 4 mm² solid/stranded. A screwdriver with a 5 to 6 mm diameter shaft is required for termination.

Frequently asked questions

How does it mount?

Screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Mounting position is unrestricted, with required clearances: 50 mm above and below, 30 mm at the sides.

MPN
3RV2011-0FA10