Skip to main content
Siemens 3RV2011-0GA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0GA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-0GA10-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, size S00, 3RV2011-0GA10-ZW96, 0.63 A rated current, Class 10 trip, 100 kA SCCR at 400 V AC, screw-type terminals, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0GA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0GA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)0.63 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0GA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range0.45 ... 0.63 A
Instantaneous short-circuit trip current8.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0GA10-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0GA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12

Mechanical

3RV2011-0GA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0GA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0GA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2011-0GA10-ZW96 is a SIRIUS-brand motor protection circuit breaker in the compact S00 frame, rated for a 0.63 A motor overload setting with Class 10 trip characteristic — meaning it will trip within 10 seconds at 7.2× the thermal setting, fast enough to protect standard induction motors during locked-rotor events without nuisance tripping on normal starts. Screw and snap-on mounting onto 35 mm standard mounting rail per DIN EN 60715, with any mounting position accepted. The 45 mm width and 97 mm cube footprint fit tightly into a motor control center bucket or standalone enclosure.

Breaking capacity and discrimination

Rated short-circuit breaking capacity reaches 100 kA at 400 V AC and 690 V AC — that is the full prospective fault current this device can interrupt without external fusing in most industrial distribution systems. At 240 V AC the same 100 kA holds. For a site electrical engineer coordinating protection, this SCCR headroom means the 3RV2011-0GA10-ZW96 can be applied downstream of a feeder breaker without requiring additional current-limiting fuses, provided the feeder's let-through does not exceed the device's withstand. Phase failure detection is built in — if one phase drops, the breaker trips, preventing single-phasing damage to the motor winding. No ground fault detection on this variant.

Termination and wiring

Screw-type terminals for the main current circuit accept 2× (0.75 to 2.5 mm²) solid or stranded, or 2× 4 mm². Screwdriver shaft diameter 5 to 6 mm. M3 terminal screws. The compact S00 frame leaves minimal finger space in a dense panel — plan terminal access from the front, with 50 mm clearance upward and downward, 30 mm to the side, and zero clearance forward.

Frequently asked questions

Where can I buy the 3RV2011-0GA10-ZW96?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What is the 3RV2011-0GA10-ZW96 used for?

It is a SIRIUS motor protection circuit breaker for protecting three-phase induction motors up to 0.63 A full-load current, with Class 10 trip characteristic and 100 kA interrupting capacity at 400 V.

Will the 3RV2011-0GA10-ZW96 drop into a panel specified around the 3RV2011-0AA10 without rewiring?

Both are S00 frame size with the same 45 mm width and DIN rail mounting, so the mechanical fit is identical. The 0GA10-ZW96 has a 0.63 A overload setting versus the 0AA10's standard rating, so verify the motor FLA matches before substitution — the terminal layout and screw-type connections are the same.

MPN
3RV2011-0GA10-ZW96