Siemens 3RV2011-0GA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0GA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-0GA10-ZX95
Active

Siemens SIRIUS 3RV2011-0GA10-ZX95, Size S00 motor protection circuit breaker, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw-type terminals, screw and snap-on mounting onto 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0GA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0GA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)0.63 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0GA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.45 ... 0.63 A
Instantaneous short-circuit trip current8.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0GA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0GA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-0GA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0GA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0GA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection breaker, Size S00 — 100 kA SCCR, Class 10

The Siemens SIRIUS 3RV2011-0GA10-ZX95 is a Size S00 motor protection circuit breaker designed for motor branch circuits. Its 100 kA breaking capacity at 400 V AC means it safely interrupts fault currents up to that level without cascading upstream — critical for high-fault panels where coordination matters. Trip Class 10 ensures the breaker trips within 10 seconds at 600% of the thermal setting, matching standard IEC motor starting profiles.

Mounting and integration

Fastens via screw and snap-on onto 35 mm DIN rail per DIN EN 60715. Mounting position any, so vertical or horizontal panel layouts work. Clearance: 50 mm above and below, 30 mm to the side, zero forward/backward — tight panel spacing is fine. Screw-type terminals on the main circuit accept 2x (0.75–2.5 mm²) solid/stranded or 2x 4 mm²; M3 screw for the main contacts.

Frequently asked questions

What is the breaking capacity of 3RV2011-0GA10-ZX95 at 400 V?

100 kA at 400 V AC — that is the rated short-circuit breaking capacity, suitable for high-fault panels.

Where can I buy 3RV2011-0GA10-ZX95 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

What is the trip class and what does it mean?

Trip Class 10 means the breaker trips within 10 seconds at 600% of the thermal setting, matching standard motor starting profiles for most induction motors.