Skip to main content
Siemens 3RV2011-0HA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0HA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-0HA10-ZW96
Active

Siemens SIRIUS 3RV2011-0HA10-ZW96, motor protection circuit breaker, size S00, CLASS 10, adjustable overload release 0.55...0.8 A, magnetic short-circuit trip 10 A, screw terminals, 100 kA breaking capacity at 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-0HA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
3RV2011-0HA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)0.8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
3RV2011-0HA10-ZW96 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current10 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
3RV2011-0HA10-ZW96 — Endurance & Switching
ParameterValue
Switching frequency, AC-3 (max.)15 1/h
3RV2011-0HA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker, size S00, 0.8 A, CLASS 10

The adjustable overload release covers 0.55 to 0.8 A, and the instantaneous magnetic short-circuit trip responds at 10 A. Rated for system voltages from 20 to 690 V AC, this breaker delivers a 100 kA breaking capacity across the 240 V to 690 V range (-).

The 3RV2011-0HA10-ZW96 carries a RoHS compliance date of 10/01/2009, indicating it meets the EU RoHS directive for restricted substances. The part is designed for motor protection per IEC/EN 60947-2 and 60947-4-1 standards. Standard documentation includes the manufacturer's datasheet and declaration of conformity covering CE, UL, and CSA certifications — these are available on request with the RFQ.

Frequently asked questions

What is 3RV2011-0HA10-ZW96's trip class?

It is CLASS 10, meaning it will trip within 10 seconds at 7.2× the overload setting — suitable for standard motor starting profiles.

What is the breaking capacity of 3RV2011-0HA10-ZW96?

100 kA at 240 V, 400 V, 500 V, and 690 V AC (-). This high SCCR rating allows it to be used in high-fault-capacity installations without requiring upstream fuses for fault protection.

Will 3RV2011-0HA10-ZW96 drop into a panel specified around 3RV1011-0HA10?

The 3RV2011-0HA10-ZW96 and 3RV1011-0HA10 share the same size S00 footprint, 45 mm width, screw-type terminals, and snap-on DIN rail mounting. The key difference is the adjustable overload range: 0.55...0.8 A for the -ZW96 versus 0.55...0.8 A for the 3RV1011-0HA10 — functionally identical for the same motor FLA. The -ZW96 variant is a multi-unit package (24 units per pack). Panel rewiring is not required for a direct swap.

How do I get current pricing and availability for 3RV2011-0HA10-ZW96?

Submit an RFQ through this listing. The part is sourced to order against your BOM line, with current pricing and confirmed lead time provided at quote time.

MPN