Siemens 3RV2011-0HA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0HA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV2011-0HA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-0HA10-ZW97, size S00, Trip Class 10, 100 kA at 400 V, screw terminals, 45 mm wide.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0HA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0HA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)0.8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-0HA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.55 ... 0.8 A
Instantaneous short-circuit trip current10 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0HA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0HA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-0HA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0HA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0HA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and what it does

The Siemens 3RV2011-0HA10-ZW97 is a SIRIUS motor protection circuit breaker, size S00, Trip Class 10. Phase failure detection is built in.

Key ratings and what they mean for fit

Breaking capacity hits 100 kA at 240 V, 400 V, 500 V, and 690 V AC — that's industrial-grade fault clearance, meaning it can sit upstream of a motor starter without needing a separate fuse for SCCR compliance in most panel builds. Rated operational voltage spans 20 to 690 V, so it covers 400 V and 480 V common bus voltages. The 45 mm width and 97 mm depth fit the S00 footprint; screw terminals accept 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm² — typical for motor branch circuits up to that cross-section. Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, any position. Clearances: 50 mm above and below, 30 mm to the side, zero forward or backward — tight panel layouts can squeeze it in. Ambient operating range -20 to +60 °C; storage and transport -50 to +80 °C.

Panel integration note

Snap-on DIN rail mounting (35 mm per DIN EN 60715) with screw-terminal main contacts (M3). The 45 mm width is one standard module — no special adapter needed. Clearance above and below is 50 mm; side clearance 30 mm. Zero forward or backward clearance means it can sit flush against a back panel or enclosure wall.

MPN
3RV2011-0HA10-ZW97