Siemens 3RV2011-0JA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV2011-0JA10-ZX95 Motor Protection Circuit B

MPN3RV2011-0JA10-ZX95
Active

Siemens SIRIUS 3RV2011-0JA10-ZX95, motor protection circuit breaker, 45 mm wide, Class 10, 100 kA breaking capacity at 400 V, screw terminals, snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-0JA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-0JA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-0JA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-0JA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-0JA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2011-0JA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2011-0JA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-0JA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for DIN-rail panels

It occupies a 45 mm wide footprint on the rail, with a depth of 97 mm and height of 97 mm, leaving 50 mm clearance above and below and 30 mm to the side for cooling and wiring access. Breaking capacity is 100 kA at 400 V AC (also at 240 V, 500 V, and 690 V AC), so it can safely interrupt a bolted fault on a high-capacity distribution panel without cascading upstream.

Mounting position is any, but the 50 mm upwards and downwards clearance must be maintained for arc quenching. Main circuit terminals accept solid or stranded wire: 2×(0.75…2.5 mm²) or 2×4 mm², terminated with M3 screws. The screw-type terminal design is standard for panel wiring — no special crimp tool needed. The part is rated for use at supply voltages from 20 V to 690 V, covering most low-voltage motor control panels.

MPN