Skip to main content
Siemens 3RV2011-0JA20-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0JA20-ZW97 SIRIUS Motor Circuit Breaker, 100

MPN3RV2011-0JA20-ZW97
Active

Siemens SIRIUS 3RV2011-0JA20-ZW97 motor-protective circuit breaker, 100 kA breaking capacity at 400 V AC, Trip Class 10, phase failure detection, spring-loaded terminals, 45 mm wide.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0JA20-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0JA20-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-0JA20-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0JA20-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0JA20-ZW97 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)

Mechanical

3RV2011-0JA20-ZW97 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0JA20-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0JA20-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens SIRIUS 3RV2011-0JA20-ZW97 is a motor-protective circuit breaker designed for motor protection in control panels. It mounts via screw and snap-on onto a 35 mm standard mounting rail per DIN EN 60715, fitting into the same DIN-rail footprint as the rest of the SIRIUS 3RV2 family. Rated breaking capacity hits 100 kA at 400 V AC — that is the short-circuit current it can safely interrupt without upstream fuses or a larger breaker taking over. The same 100 kA holds at 500 V and 690 V AC, so it handles high-fault panels without cascading. Trip Class 10 opens within 10 seconds. Phase failure detection is built in.

Mounting and wiring

Width is 45 mm, depth 97 mm, height 106 mm — a compact two-module-wide footprint that leaves room for contactors and overloads on the same rail. Mounting position is any orientation, which simplifies layout in tight enclosures. Main circuit connections use spring-loaded terminals accepting 2× (0.5 to 4 mm²) solid or stranded wire. No screw torque to check, no re-tightening on thermal cycles — just strip to the right length and push in. Clearance distances: 50 mm upwards and downwards, 30 mm at the sides, 0 mm forwards and backwards. That 0 mm backwards means it can sit flush against the back panel or another device.

Frequently asked questions

Will 3RV2011-0JA20-ZW97 drop into a panel specified around 3RV2011-0BA20 without rewiring?

Both are SIRIUS 3RV2 motor-protective breakers with the same 45 mm width, DIN-rail snap-on mounting, and spring-loaded terminals — so the footprint and wiring method are identical. The difference is in the internal trip characteristics and accessory compatibility; verify the thermal setting range and any special-function modules (like undervoltage releases) before swapping.

MPN